On Sun, May 22, 2011 at 5:35 PM, Tony Graziano <[email protected]
> wrote:

> They are still orderable/in stock for around 160.00 off the net.
>
> It is much easier to sping up a wifi connection with no security for it to
> get its config file the first time, then it will store its wifi config file
> (try punching in the 26 characters on the handset drives the person behind
> the phone to senselessness).
>
> Other than a time and group phone setting thing it seems ok to me.
>
>
> On Sun, May 22, 2011 at 5:32 PM, Tony Graziano <
> [email protected]> wrote:
>
>> Thanks. I had the chance to test this plugin and found the following
>> oddities:
>>
>> 1. Time -  When the phone reached the configuration server and booted up,
>> time was off (used GMT instead of the timezone "47" (for example, for New
>> York). If you manually toggle the phone to New York from the handset it
>> takes. For some reason it is not applying from the config file.
>>
>> 2. Groups -  When creating a PHONE GROUP the first part of the resulting
>> handset config file is MINUS the user credentials. As a result, the GROUP
>> setting cannot be used.
>>
>>  On Sun, May 22, 2011 at 4:30 PM, Peter van der Salm <
>> [email protected]> wrote:
>>
>>>  Hi All,
>>>
>>> The current phone plug in for the Unidata WPU-7700 phone does not work in
>>> 4.4.0 of 2011-04-19.
>>> The .jar file is not the correct version.
>>>
>>> To solve this do the following:
>>>
>>> # cd /usr/share/java/sipXecs/sipXconfig
>>> # mv unidata-phones.jar unidata-phones.jar.old
>>>
>>> and copy the attached unidata-phones.jar into
>>> /usr/share/java/sipXecs/sipXconfig
>>>
>>> If you use the standard template settings, I strongly suggest to set the
>>> sip timers to either 0 (=off) or to much longer values than the current 500
>>> msec. Actually they should be something like 64 times the expected roundtrip
>>> time for the phone, which could be quite long due to power saving in the
>>> WiFi.
>>>
>>> Good luck!
>>>
>>> Peter van der Salm
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>> _______________________________________________
>>> sipx-users mailing list
>>> [email protected]
>>> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>>>
>>
>>
>>
>> --
>> ======================
>> Tony Graziano, Manager
>> Telephone: 434.984.8430
>> sip: [email protected]
>> Fax: 434.326.5325
>>
>> Email: [email protected]
>>
>> LAN/Telephony/Security and Control Systems Helpdesk:
>> Telephone: 434.984.8426
>> sip: [email protected]
>>
>> Helpdesk Contract Customers:
>> http://support.myitdepartment.net
>>
>> <http://support.myitdepartment.net>Blog:
>> http://blog.myitdepartment.net
>>
>> Linked-In Profile: http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4
>>
>>
>
>
> --
> ======================
> Tony Graziano, Manager
> Telephone: 434.984.8430
> sip: [email protected]
> Fax: 434.326.5325
>
> Email: [email protected]
>
> LAN/Telephony/Security and Control Systems Helpdesk:
> Telephone: 434.984.8426
> sip: [email protected]
>
> Helpdesk Contract Customers:
> http://support.myitdepartment.net
>
> <http://support.myitdepartment.net>Blog:
> http://blog.myitdepartment.net
>
> Linked-In Profile: http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4
>
>

I spoke too soon.It may no longer be available! I also do not see a plugin
for the 7800 yet.