Ask them to send invites for inbound calls to port 5080 and make sure the
firewall does the same (5080:5080).
On Feb 7, 2012 2:06 PM, "Mark Roseboom" <[email protected]> wrote:

> Currently, the provider is sending calls to 5060, however in our network
> configuration, the sipxec server is behind a firewall, so I am forwarding
> port 5060 requests to port 5080 on our sipxec. The provider is IIS
> Group. You are correct on hold or transfers don't work for inbound calls.
> Is this port forwarding configuration enough or do I need to have the
> provider send requests to port 5080?
>
> On Tue, Feb 7, 2012 at 1:59 PM, Tony Graziano <
> [email protected]> wrote:
>
>> Is the provider sending calls to port 5080 or 5060? Who is the provider.
>> Calls need to be sent to port 5080. Does this mean transfers don't work? If
>> so check or ask the provider to send invites to port 5080.
>> On Feb 7, 2012 1:54 PM, "Mark Roseboom" <[email protected]>
>> wrote:
>>
>>> Using sipXecs 4.4. Inbound and outbound calls work with my ITSP.
>>>
>>> Placing a call on hold works when calling any internal extension. On
>>> hold also works when making an outbound call through SIP trunk.
>>>
>>> However when an inbound call comes in, and its placed on hold, the call
>>> is dropped. Thinking it must be a NAT / firewall issue.
>>>
>>> Not sure what other diagnostics to give, please let me know.
>>>
>>> Thanks.
>>>
>>> Mark
>>>
>>> _______________________________________________
>>> sipx-users mailing list
>>> [email protected]
>>> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>>>
>>
>> LAN/Telephony/Security and Control Systems Helpdesk:
>> Telephone: 434.984.8426
>> sip: [email protected].**net<[email protected]>
>>
>> Helpdesk Customers: 
>> http://myhelp.myitdepartment.**net<http://myhelp.myitdepartment.net>
>> Blog: http://blog.myitdepartment.net
>>
>> _______________________________________________
>> sipx-users mailing list
>> [email protected]
>> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>>
>
>
> _______________________________________________
> sipx-users mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>

-- 
LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
sip: [email protected]

Helpdesk Customers: http://myhelp.myitdepartment.net
Blog: http://blog.myitdepartment.net
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to