I believe that is what I was saying to Joe, he needs to enable the T.38
capability in his gateway for his fax to work.

 

Tony, are you saying that a call into a gateway with t.38 enabled, and
coming from a fax that is connected to the PSTN via an analog trunk does not
work?    

 

From: [email protected]
[mailto:[email protected]] On Behalf Of Tony Graziano
Sent: Tuesday, March 13, 2012 2:06 PM
To: Discussion list for users of sipXecs software
Subject: Re: [sipx-users] Is fax supposed to work w/o t.38?

 

It is not designed to work with t.30, only t.38. T.38 is a requirement.

On Mar 13, 2012 4:57 PM, "Todd Hodgen" <[email protected]> wrote:

Joe,  I think if you enable t.38 in your gateway, things will begin to work.
I have customers receiving calls via PSTN connected fax machines, PRI
gateway has T.38 enabled, they are forwarded to customer voicemail account.
I did have to go into the gateway and turn on T.38 for it to start working.

-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Joe Micciche
Sent: Tuesday, March 13, 2012 1:37 PM
To: Discussion list for users of sipXecs software
Subject: [sipx-users] Is fax supposed to work w/o t.38?

-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

I read through many of the threads and JIRAs about fax, but this wasn't
clear. In sipXecs 4.4, is fax via PCMU supposed to work? or is it designed
to work with only t.38?

I tested a fax: the machine dialed to sipXecs via a gateway @g711U and the
session was 44 secs (1 page). I received the fax notification via email, but
the tiff was 0 bytes. The analog fax indicated success.

In looking at a trace of the session, FS is sending a reINVITE and offering
t.38; my gateway replies 488/Not Acceptable Media (since it is only set up
for g711u at the moment), and the session is terminated at the 3 second
mark.

- --
==================================================================
Joe Micciche                            [email protected]
Red Hat, Inc.                           http://www.redhat.com
Senior Communications Engineer          X (81) 44554
+1.919.754.4554                         Key: 65F90FE1
==================================================================

-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.12 (GNU/Linux)
Comment: Using GnuPG with Mozilla - http://enigmail.mozdev.org/

iEYEARECAAYFAk9fr+oACgkQJHjEUGX5D+FEsgCfQPdeKzUe10i5FCpXc2E676I/
30IAoIVguE0f3kFkDO4aBnEx1W6vhwaQ
=ickS
-----END PGP SIGNATURE-----
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

 

LAN/Telephony/Security and Control Systems Helpdesk:

Telephone: 434.984.8426

sip: [email protected]

 

Helpdesk Customers: http://myhelp.myitdepartment.net

Blog: http://blog.myitdepartment.net

_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to