I meant when I make an incoming call, not outgoing. And, yes, I did use
the template this time. Still on 4.2 at this point. Will not be able to
reinstall today.
Also, my SIP Trunk to callwithus is as you say:
Src IP Src Port Dst IP Dst Port Protocol Src Iface Dst Iface Flow
Type IPS Category Expiry (sec) Tx Bytes Rx Bytes Tx Pkts Rx Pkts
xxx.xxx.xxx.xxx (sipx server)
5080 204.74.213.5 (sip.callwithus.com)
5060 UDP X3 X1 SIP Control N/A 27 31060
17578 248 49
I do not know why voip.ms is backwards.
Stiles
On 03/27/2012 03:49 PM, Tony Graziano wrote:
That looks wrong. The destination port for an outbound call should be
5060 not 5080. If you used the stock template the firewall is he issue
here.
On Mar 27, 2012 3:38 PM, "Stiles Watson" <[email protected]
<mailto:[email protected]>> wrote:
I have a Sonicwall NSA 240. I've gone back and deleted all the
firewall rules and NAT policies related to sipx and only created
new ones for 5080 UDP and 30000-31000 UDP, leaving 5060 blocked at
this point. Sip transformations is turned off and Consistent NAT
is turned on. When I make a call I see the following in the
Sonicwall's Connections Monitor:
# Src IP Src Port Dst IP Dst Port Protocol Src
Iface Dst
Iface Flow Type IPS Category Expiry (sec) Tx Bytes
Rx Bytes
Tx Pkts Rx Pkts
1 174.34.146.162 (atlanta.voip.ms <http://atlanta.voip.ms>)
18530 xxx.xxx.xxx.xxx (sipx server)
30000 UDP X1 X3
N/A 29 837786 754800 4259 3774
2 174.34.146.162 5060 xxx.xxx.xxx.xxx 5080 UDP X1
X3 SIP
Control N/A 21 6335 5586 10 12
Connection #2, the SIP Control, is the registration connection and
stays live all the time. #1 above only appears when there is an
active call.
Stiles
On 03/27/2012 12:25 PM, Gerald Drouillard wrote:
On 3/27/2012 12:03 PM, Stiles Watson wrote:
This is where one swallows one's pride.... The way I was
entering data caused the drop-down to not be displayed.
To keep this short:
1. When you first select Add new gateway>Sip Trunk, the
template drop down is not visible. I was not aware this was
the case until yesterday. I just thought it was not there.
2. The template drop-down is only displayed after you enter a
name for the gateway and then select the default SBC.
3. If you ever click the Apply button before both the name and
SBC are entered, the drop down is never displayed.
This is why I never saw the template drop-down.
Now, having said all of that, I deleted my existing voip.ms
<http://voip.ms> gateway and created a new one using the
template drop-down. However, this did not fix my problem and
everything is as it was before. I still can not retrieve a call
from hold or cancel a transfer. I have verified in my voip.ms
<http://voip.ms> account that it is registered with the public
IP and port 5080.
So it looks like we are back to a firewall problem, correct?
Yes. What kind of firewall do you have?
--
Regards
--------------------------------------
Gerald Drouillard
Technology Architect
Drouillard& Associates, Inc.
http://www.Drouillard.biz
_______________________________________________
sipx-users mailing list
[email protected] <mailto:[email protected]>
List Archive:http://list.sipfoundry.org/archive/sipx-users/
_______________________________________________
sipx-users mailing list
[email protected] <mailto:[email protected]>
List Archive: http://list.sipfoundry.org/archive/sipx-users/
LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
sip: [email protected]
<mailto:[email protected]>
Helpdesk Customers: http://myhelp.myitdepartment.net
<http://myhelp.myitdepartment.net>
Blog: http://blog.myitdepartment.net
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/