the system will project the config file with the mac address that was
configured. Don't manipulate the file name. Delete the phone and
create it with the proper mac address and project the file or you will
never get updates.

On Wed, Jul 11, 2012 at 11:47 AM, Kurt Albershardt <[email protected]> wrote:
>
> On Jul 11, 2012, at 9:40 , Kurt Albershardt wrote:
>
>> As it turns out, I mis-read a "B" as an "8" when entering the MAC of the 
>> second phone above.
>>
>> Went into 'Phones" in the GUI and changed the MAC to the correct 
>> 0004133842b5, then hit "OK" and "Send Profiles"
>> Saw "You are about to generate new configuration profiles for 1 device. 
>> Press OK to proceed."
>> then "1 profile will be generated. Go to Job Status page to monitor 
>> operation progress."
>>
>> Job Status says:
>>
>> Projection for: 0004133842b5 7/11/12 3:31 PM 7/11/12 3:31 PM Failed 
>> Invocation of method 'getValue' in class 
>> org.sipfoundry.sipxconfig.setting.ConditionalSettingImpl threw exception 
>> java.lang.NullPointerException @ snom/snom.vm[17,63]
>> Restarting: 0004133842b5 7/11/12 3:31 PM 7/11/12 3:31 PM Failed Timed out 
>> waiting for response
>
> Left out the directory listing (after this and before I renamed the config 
> file):
>
> root@sipx docroot]# ls -l
> total 168
> -rw-r--r-- 1 sipx sipx 51932 Jul 10 17:51 00041338400C.xml
> -rw-r--r-- 1 sipx sipx 51932 Jul 10 17:51 000413384285.xml
> -rw-r--r-- 1 sipx sipx     0 Jul 11 09:37 0004133842B5.xml
> -rw-r--r-- 1 sipx sipx 51932 Jul 10 17:51 0004133842E0.xml
>
>
> _______________________________________________
> sipx-users mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users/



-- 
~~~~~~~~~~~~~~~~~~
Tony Graziano, Manager
Telephone: 434.984.8430
sip: [email protected]
Fax: 434.465.6833
~~~~~~~~~~~~~~~~~~
Linked-In Profile:
http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4
Ask about our Internet Fax services!
~~~~~~~~~~~~~~~~~~

Using or developing for sipXecs from SIPFoundry? Ask me about sipX-CoLab 2013!

-- 
LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
sip: [email protected]

Helpdesk Customers: http://myhelp.myitdepartment.net
Blog: http://blog.myitdepartment.net
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to