Hi, I’m struggling with a Polycom related problem. This is more Polycom related than SipX but I think here are a lot of people that know Polycom phones very well.
In some cases my Polycom does not play the user-busy tone. When calling pstn using ISDN it depends on the other side. The case that works: - ISDN Alerting arrives -> 180 Ringing to phone - ISDN Disconnect user-busy arrives -> 486 Busy here to phone The case that does not work: - ISDN Disconnect user-busy arrives -> 486 Busy here to phone The polycom seems to play the busy-tone only if there was a 180 RINGING before the 486 Busy here. Does anybody know if there is an option that I can set from SipX to manipulate this behavior? Sincerely Jan _____________________________ Jan Fricke (B.Sc.) *IANT - APPLIED NGN-TECHNOLOGIES **Turn-Key VoIP/UC Solutions and More... *IANT GmbH Salzdahlumer Straße 46/48 D-38302 Wolfenbüttel Fon: +49 (5331) 6794 0 Fax: +49 (5331) 6794 499 Mail: [email protected] Web: www.iant.de <http://www.iant.de/en/startseite> IANT is eZuce <http://www.ezuce.com/> Elite Partner for EMEA IANT is Member of GROUPLINK <http://www.grouplink.de/> Banking Connections: IANT GmbH, Volksbank BraWo, Konto-Nr. 12 95 98 50 00, BLZ 269 910 66, IBAN-No.: DE02 2699 1066 1295 9850 00, BIC: GENODEF1WOB; Steuer-Nr.: 51 203 01203; VAT: DE264352710; HRB 201710, Amtsgericht Braunschweig; CEO: Dipl.-Ing. Jan Schumacher, Prof. Dr.-Ing. Diederich Wermser This e-mail may contain confidential and/or privileged information. If you are not the intended recipient or have received this e-mail in error please notify the sender immediately and delete this e-mail.