found on smartmontools-support.
smartctl version 5.32 Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: QUANTUM FIREBALL CR6.4A
Serial Number: 926919322843
Firmware Version: A5U.1400
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 4
ATA Standard is: ATA/ATAPI-4 T13 1153D revision 15
Local Time is: Tue Jan 25 22:00:17 2005 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
The SMART RETURN STATUS return value (smartmontools -H option/Directive)
can not be retrieved with this version of ATAng, please do not rely on this
value
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 2) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SMART Attributes Data Structure revision number: 9
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail Offline -
0
3 Spin_Up_Time 0x0027 077 076 020 Pre-fail Always -
2975
4 Start_Stop_Count 0x0032 099 099 008 Old_age Always -
1003
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail Always -
0
7 Seek_Error_Rate 0x000b 100 093 023 Pre-fail Always -
0
9 Power_On_Hours 0x0012 077 077 001 Old_age Always -
15688
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail Always -
0
12 Power_Cycle_Count 0x0032 099 099 008 Old_age Always -
982
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail Always -
0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age Always -
0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline -
0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Vendor offline Fatal or unknown error 130% 0 -
# 2 Reserved offline Fatal or unknown error 130% 1
587202877
Device does not support Selective Self Tests/Logging
-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database