Hello,
Here are the outputs for two Seagate Barracuda 1.5TB ST31500341AS. Their serial numbers have been verified on seagate's website and reported with no problem. The logs come from latest smartmontool cvs version (5.39 as of 2009-02-28 at about 23:30). One of the drive is attached on a serial-ata pci card, and the other one on a pata->sata adapter (to allow booting from BIOS on my old computer - yes I know this is not the most efficient configuration). The annoying problem is that I start to receive mails from smartd because of a misunderstood value about temperature. Data follow. Anyway thanks for smartmontools development and maintaining it. Best regards, david ############################################################################### smartctl 5.39 2009-02-28 18:26 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.11 family Device Model: ST31500341AS Serial Number: 9VS0TZRF Firmware Version: CC1H User Capacity: 1 500 301 910 016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Sat Feb 28 23:38:04 2009 CET ==> WARNING: There are known problems with these drives, see the following Seagate web pages: http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207931 http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207951 http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207957 SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 617) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 255) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 114 100 006 Pre-fail Always - 70100570 3 Spin_Up_Time 0x0003 100 100 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 26 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 064 060 030 Pre-fail Always - 2675399 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 308 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 037 020 Old_age Always - 26 184 Unknown_Attribute 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Unknown_Attribute 0x0032 100 086 000 Old_age Always - 78 189 High_Fly_Writes 0x003a 084 084 000 Old_age Always - 16 190 Airflow_Temperature_Cel 0x0022 044 041 045 Old_age Always FAILING_NOW 56 (1 167 59 39) 194 Temperature_Celsius 0x0022 056 059 000 Old_age Always - 56 (0 18 0 0) 195 Hardware_ECC_Recovered 0x001a 041 023 000 Old_age Always - 70100570 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 148545738899764 241 Unknown_Attribute 0x0000 100 253 000 Old_age Offline - 1950098783 242 Unknown_Attribute 0x0000 100 253 000 Old_age Offline - 4111473072 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 308 - # 2 Short offline Completed without error 00% 167 - # 3 Short offline Completed without error 00% 144 - # 4 Extended offline Completed without error 00% 125 - # 5 Short offline Completed without error 00% 120 - # 6 Short offline Completed without error 00% 96 - # 7 Short offline Completed without error 00% 72 - # 8 Short offline Completed without error 00% 48 - # 9 Extended offline Completed without error 00% 4 - #10 Short offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. ############################################################################### smartctl 5.39 2009-02-28 18:26 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.11 family Device Model: ST31500341AS Serial Number: 9VS0VX6B Firmware Version: CC1H User Capacity: 1 500 301 910 016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Sat Feb 28 23:37:59 2009 CET ==> WARNING: There are known problems with these drives, see the following Seagate web pages: http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207931 http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207951 http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207957 SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 609) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 255) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 117 100 006 Pre-fail Always - 149322872 3 Spin_Up_Time 0x0003 100 100 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 24 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 063 060 030 Pre-fail Always - 2554991 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 286 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 24 184 Unknown_Attribute 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 189 High_Fly_Writes 0x003a 097 097 000 Old_age Always - 3 190 Airflow_Temperature_Cel 0x0022 045 043 045 Old_age Always FAILING_NOW 55 (0 38 57 38) 194 Temperature_Celsius 0x0022 055 057 000 Old_age Always - 55 (0 18 0 0) 195 Hardware_ECC_Recovered 0x001a 036 031 000 Old_age Always - 149322872 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 24502788423966 241 Unknown_Attribute 0x0000 100 253 000 Old_age Offline - 21894754 242 Unknown_Attribute 0x0000 100 253 000 Old_age Offline - 1845717767 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 286 - # 2 Short offline Completed without error 00% 122 - # 3 Extended offline Completed without error 00% 103 - # 4 Short offline Completed without error 00% 98 - # 5 Short offline Completed without error 00% 74 - # 6 Short offline Completed without error 00% 50 - # 7 Short offline Completed without error 00% 26 - # 8 Extended offline Completed without error 00% 14 - # 9 Short offline Completed without error 00% 10 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. ############################################################################### log ends ------------------------------------------------------------------------------ Open Source Business Conference (OSBC), March 24-25, 2009, San Francisco, CA -OSBC tackles the biggest issue in open source: Open Sourcing the Enterprise -Strategies to boost innovation and cut costs with open source participation -Receive a $600 discount off the registration fee with the source code: SFAD http://p.sf.net/sfu/XcvMzF8H _______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database