-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 Yo All!
New drive: WDC WD5000AADS-00L4B1 See attached results of: smartctl -t short -T permissive /dev/sdd sleep 180 smartctl -a -T permissive /dev/sdd RGDS GARY - --------------------------------------------------------------------------- Gary E. Miller Rellim 109 NW Wilmington Ave., Suite E, Bend, OR 97701 g...@rellim.com Tel:+1(541)382-8588 -----BEGIN PGP SIGNATURE----- Version: GnuPG v1.4.3 (GNU/Linux) iD8DBQFKaMwbBmnRqz71OvMRAhpwAJ97OisFghTTLRTZfzRogcHjxTzhwACg2dob Ly43H3jlW9FKLuOKLW4BBbM= =vqCs -----END PGP SIGNATURE-----
smartctl version 5.38 [x86_64-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: WDC WD5000AADS-00L4B1 Serial Number: WD-WCAUH1315207 Firmware Version: 05.04C05 User Capacity: 500,107,862,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Thu Jul 23 13:09:55 2009 PDT SMART support is: Available - device has SMART capability. SMART support is: Enabled Error SMART Status command failed Please get assistance from http://smartmontools.sourceforge.net/ Values from ATA Return Descriptor are: 00 09 0c 00 00 00 00 00 00 00 00 00 00 00 00 === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (12000) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 140) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 178 178 021 Pre-fail Always - 4058 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 7 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 1 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 5 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 4 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 7 194 Temperature_Celsius 0x0022 121 116 000 Old_age Always - 26 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 1 - # 2 Extended offline Aborted by host 70% 1 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database