-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Yo All!

A new drive not in the database:
        HDT721010SLA360

See attached output of:
        smartctl -a /dev/sdd > /tmp/HDT721010SLA360.txt


RGDS
GARY
- ---------------------------------------------------------------------------
Gary E. Miller Rellim 109 NW Wilmington Ave., Suite E, Bend, OR 97701
        g...@rellim.com  Tel:+1(541)382-8588
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.3 (GNU/Linux)

iD8DBQFKaM1PBmnRqz71OvMRAnbEAJ97lsVqPL0vUL8Zn8tWqY70lw/+dwCfZkfH
O/RT3QIubgjub2a/JDhU6FU=
=UTbj
-----END PGP SIGNATURE-----
smartctl version 5.38 [x86_64-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     Hitachi HDT721010SLA360
Serial Number:    STF604MH0DJLLB
Firmware Version: ST6OA31B
User Capacity:    1,000,204,886,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Thu Jul 23 13:49:27 2009 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (14090) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 235) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   099   099   016    Pre-fail  Always       
-       131072
  2 Throughput_Performance  0x0005   132   132   054    Pre-fail  Offline      
-       113
  3 Spin_Up_Time            0x0007   100   100   024    Pre-fail  Always       
-       337
  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       
-       6
  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0005   125   125   020    Pre-fail  Offline      
-       33
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       
-       4004
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       6
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       167
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       
-       167
194 Temperature_Celsius     0x0002   181   181   000    Old_age   Always       
-       33 (Lifetime Min/Max 24/38)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       
-       35

SMART Error Log Version: 1
ATA Error Count: 35 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 35 occurred at disk power-on lifetime: 3875 hours (161 days + 11 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 f0 be 25 ed e3  Error: ICRC, ABRT 240 sectors at LBA = 0x03ed25be = 
65873342

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 80 2e 24 ed e0 08  25d+14:23:41.600  READ DMA EXT
  25 00 00 2e 20 ed e0 08  25d+14:23:41.600  READ DMA EXT
  25 00 00 2e 1c ed e0 08  25d+14:23:41.600  READ DMA EXT
  25 00 00 2e 18 ed e0 08  25d+14:23:41.500  READ DMA EXT
  25 00 80 ae 14 ed e0 08  25d+14:23:41.500  READ DMA EXT

Error 34 occurred at disk power-on lifetime: 3875 hours (161 days + 11 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 20 0e f7 ad e3  Error: ICRC, ABRT 32 sectors at LBA = 0x03adf70e = 
61732622

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 80 ae f6 ad e0 08  25d+14:22:06.000  READ DMA EXT
  c8 00 80 2e f6 ad e3 08  25d+14:22:06.000  READ DMA
  c8 00 80 ae f5 ad e3 08  25d+14:22:06.000  READ DMA
  c8 00 00 ae f4 ad e3 08  25d+14:22:05.900  READ DMA
  c8 00 00 ae f3 ad e3 08  25d+14:22:05.900  READ DMA

Error 33 occurred at disk power-on lifetime: 3875 hours (161 days + 11 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 00 ae ed 23 e3  Error: ICRC, ABRT at LBA = 0x0323edae = 52686254

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 80 2e ec 23 e0 08  25d+14:18:44.700  READ DMA EXT
  25 00 00 2e e8 23 e0 08  25d+14:18:44.700  READ DMA EXT
  c8 00 00 2e e7 23 e3 08  25d+14:18:44.700  READ DMA
  25 00 00 2e e3 23 e0 08  25d+14:18:44.700  READ DMA EXT
  25 00 00 2e df 23 e0 08  25d+14:18:44.700  READ DMA EXT

Error 32 occurred at disk power-on lifetime: 3875 hours (161 days + 11 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 50 de b1 7e e2  Error: ICRC, ABRT 80 sectors at LBA = 0x027eb1de = 
41857502

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 00 2e b1 7e e2 08  25d+14:14:56.800  READ DMA
  c8 00 00 2e b0 7e e2 08  25d+14:14:56.800  READ DMA
  c8 00 80 ae af 7e e2 08  25d+14:14:56.800  READ DMA
  c8 00 80 2e af 7e e2 08  25d+14:14:56.800  READ DMA
  c8 00 80 ae ae 7e e2 08  25d+14:14:56.800  READ DMA

Error 31 occurred at disk power-on lifetime: 3875 hours (161 days + 11 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 00 ae 5d 33 e1  Error: ICRC, ABRT at LBA = 0x01335dae = 20143534

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 00 ae 5c 33 e0 08  25d+13:50:46.700  READ DMA EXT
  25 00 00 ae 58 33 e0 08  25d+13:50:46.700  READ DMA EXT
  c8 00 00 ae 57 33 e1 08  25d+13:50:46.700  READ DMA
  25 00 00 ae 53 33 e0 08  25d+13:50:46.700  READ DMA EXT
  25 00 00 ae 4f 33 e0 08  25d+13:50:46.700  READ DMA EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      3992         -
# 2  Short offline       Completed without error       00%      3968         -
# 3  Short offline       Completed without error       00%      3944         -
# 4  Extended offline    Completed without error       00%      3941         -
# 5  Short offline       Completed without error       00%      3920         -
# 6  Short offline       Completed without error       00%      3896         -
# 7  Extended offline    Interrupted (host reset)      80%      3875         -
# 8  Short offline       Completed without error       00%      3872         -
# 9  Short offline       Completed without error       00%      3848         -
#10  Short offline       Completed without error       00%      3824         -
#11  Short offline       Completed without error       00%      3800         -
#12  Short offline       Completed without error       00%      3777         -
#13  Short offline       Completed without error       00%      3753         -
#14  Short offline       Completed without error       00%      3729         -
#15  Extended offline    Completed without error       00%      3724         -
#16  Short offline       Completed without error       00%      3705         -
#17  Short offline       Completed without error       00%      3680         -
#18  Short offline       Completed without error       00%      3656         -
#19  Short offline       Completed without error       00%      3632         -
#20  Short offline       Completed without error       00%      3608         -
#21  Short offline       Completed without error       00%      3584         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to