I downloaded via web interface latest version of smarttools; SVN was not 
correctly inserted that way, so the version information is wrong

Intel(r) X25-E Extreme SATA Solid-State Drive special attributes:
E1h Host Writes Count
E8h Available reserved space
E9h Media Wearout Indicator

More info can be found at the "Intel(r) High Performance SSD S.M.A.R.T. 
features user's guide" (via 
http://www3.intel.com/cd/channel/reseller/apac/eng/products/nand/tech/index.htm 
; needs Intel registration)

regards
Michael

------------------------------------------------------------------------
Michael Hebenstreit                 Senior Cluster Architect
Intel Corporation                   Software and Services Group/DRD
2800 N Center Dr, DP3-307           Tel.:   +1 253 371 3144
WA 98327, DuPont
UNITED STATES                       E-mail: michael.hebenstr...@intel.com


smartctl 5.39 20091007 r5.39 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     SSDSA2SH032G1GN INTEL
Serial Number:    CVEM8374001P032HGN
Firmware Version: 045C8620
User Capacity:    32,000,000,000 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 1
Local Time is:    Wed Oct  7 12:03:37 2009 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 (   1) seconds.
Offline data collection
capabilities:                    (0x75) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Abort Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (   5) minutes.
Conveyance self-test routine
recommended polling time:        (   1) minutes.

SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  3 Spin_Up_Time            0x0000   100   000   000    Old_age   Offline      
-       0
  4 Start_Stop_Count        0x0000   100   000   000    Old_age   Offline      
-       0
  5 Reallocated_Sector_Ct   0x0002   100   100   000    Old_age   Always       
-       0
  9 Power_On_Hours          0x0002   100   100   000    Old_age   Always       
-       3976
 12 Power_Cycle_Count       0x0002   100   100   000    Old_age   Always       
-       31
192 Power-Off_Retract_Count 0x0002   100   100   000    Old_age   Always       
-       12
232 Unknown_Attribute       0x0003   100   100   010    Pre-fail  Always       
-       0
233 Unknown_Attribute       0x0002   099   099   000    Old_age   Always       
-       0
225 Load_Cycle_Count        0x0000   200   200   000    Old_age   Offline      
-       69246

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      3976         -

Note: selective self-test log revision number (0) not 1 implies that no 
selective self-test has ever been run
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been 
run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Come build with us! The BlackBerry(R) Developer Conference in SF, CA
is the only developer event you need to attend this year. Jumpstart your
developing skills, take BlackBerry mobile applications to market and stay 
ahead of the curve. Join us from November 9 - 12, 2009. Register now!
http://p.sf.net/sfu/devconference
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to