smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce 
Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD10EAVS-00M4B0
Serial Number:    WD-WCAV51977785
Firmware Version: 01.00A01
User Capacity:    1,000,204,886,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Tue Nov 17 18:04:23 2009 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

Error SMART Status command failed
Please get assistance from http://smartmontools.sourceforge.net/
Values from ATA Return Descriptor are:
 00     09 0c 00 00 00 00 00 00  00 4f 00 00 00 00                              
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x80) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (19980) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 230) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.
SCT capabilities:              (0x303f) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   253   051    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0027   117   116   021    Pre-fail  Always       
-       7141
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       16
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x002e   100   253   000    Old_age   Always       
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       1
 10 Spin_Retry_Count        0x0032   100   253   000    Old_age   Always       
-       0
 11 Calibration_Retry_Count 0x0032   100   253   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       11
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       
-       7
193 Load_Cycle_Count        0x0032   200   200   000    Old_age   Always       
-       38
194 Temperature_Celsius     0x0022   112   112   000    Old_age   Always       
-       35
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   100   253   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x0008   100   253   000    Old_age   Offline      
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%         1         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day 
trial. Simplify your report design, integration and deployment - and focus on 
what you do best, core application coding. Discover what's new with
Crystal Reports now.  http://p.sf.net/sfu/bobj-july
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to