Dear All,
Here is the output of a drive installed in a HP ProLiant SL170z G6
server. Using SMARTMONTOOLS 5.39 states that it is not in the database.
Thanks, Cheers, Eric.
smartctl 5.39 2009-01-15 22:52 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-8 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: MM0500EANCR
Serial Number: 9SP134E5
Firmware Version: HPG1
User Capacity: 500,107,862,016 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 6
Local Time is: Sat Feb 6 12:44:01 2010 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 659) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 121) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 066 063 044 Pre-fail Always
- 4523310
3 Spin_Up_Time 0x0003 100 100 000 Pre-fail Always
- 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always
- 12
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always
- 0
7 Seek_Error_Rate 0x000f 062 060 030 Pre-fail Always
- 1588066
9 Power_On_Hours 0x0032 099 099 000 Old_age Always
- 1115
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always
- 12
180 Unknown_Attribute 0x003b 100 100 030 Pre-fail Always
- 678203
184 Unknown_Attribute 0x0032 100 100 003 Old_age Always
- 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always
- 0
188 Unknown_Attribute 0x0032 100 100 000 Old_age Always
- 0
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always
- 0
190 Airflow_Temperature_Cel 0x0022 074 044 045 Old_age Always
In_the_past 26 (0 2 26 20)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always
- 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 11
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always
- 12
194 Temperature_Celsius 0x0022 026 056 000 Old_age Always
- 26 (0 19 0 0)
195 Hardware_ECC_Recovered 0x001a 016 016 000 Old_age Always
- 4523310
196 Reallocated_Event_Count 0x0033 100 100 036 Pre-fail Always
- 0
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 1115 -
# 2 Short offline Completed without error 00% 1093 -
# 3 Short offline Completed without error 00% 1069 -
# 4 Short offline Completed without error 00% 1025 -
# 5 Short offline Completed without error 00% 1001 -
# 6 Extended offline Completed without error 00% 979 -
# 7 Short offline Completed without error 00% 953 -
# 8 Short offline Completed without error 00% 929 -
# 9 Short offline Completed without error 00% 905 -
#10 Short offline Completed without error 00% 881 -
#11 Short offline Completed without error 00% 857 -
#12 Short offline Completed without error 00% 833 -
#13 Extended offline Completed without error 00% 811 -
#14 Short offline Completed without error 00% 785 -
#15 Short offline Completed without error 00% 761 -
#16 Short offline Completed without error 00% 737 -
#17 Short offline Completed without error 00% 713 -
#18 Short offline Completed without error 00% 689 -
#19 Short offline Completed without error 00% 665 -
#20 Extended offline Completed without error 00% 643 -
#21 Short offline Completed without error 00% 617 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
The Planet: dedicated and managed hosting, cloud storage, colocation
Stay online with enterprise data centers and the best network in the business
Choose flexible plans and management services without long-term contracts
Personal 24x7 support from experience hosting pros just a phone call away.
http://p.sf.net/sfu/theplanet-com
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database