Dear All,

     Here is the output of a drive installed in a HP ProLiant SL170z G6
server. Using SMARTMONTOOLS 5.39 states that it is not in the database.

Thanks, Cheers, Eric.
smartctl 5.39 2009-01-15 22:52 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-8 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     MM0500EANCR
Serial Number:    9SP134E5
Firmware Version: HPG1
User Capacity:    500,107,862,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 6
Local Time is:    Sat Feb  6 12:44:01 2010 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                  ( 659) seconds.
Offline data collection
capabilities:                     (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:         (   2) minutes.
Extended self-test routine
recommended polling time:         ( 121) minutes.
Conveyance self-test routine
recommended polling time:         (   3) minutes.
SCT capabilities:               (0x103f)  SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   066   063   044    Pre-fail  Always       
-       4523310
  3 Spin_Up_Time            0x0003   100   100   000    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       
-       12
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   062   060   030    Pre-fail  Always       
-       1588066
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       
-       1115
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       
-       12
180 Unknown_Attribute       0x003b   100   100   030    Pre-fail  Always       
-       678203
184 Unknown_Attribute       0x0032   100   100   003    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
188 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       
-       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0022   074   044   045    Old_age   Always   
In_the_past 26 (0 2 26 20)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       
-       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       11
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       
-       12
194 Temperature_Celsius     0x0022   026   056   000    Old_age   Always       
-       26 (0 19 0 0)
195 Hardware_ECC_Recovered  0x001a   016   016   000    Old_age   Always       
-       4523310
196 Reallocated_Event_Count 0x0033   100   100   036    Pre-fail  Always       
-       0
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      1115         -
# 2  Short offline       Completed without error       00%      1093         -
# 3  Short offline       Completed without error       00%      1069         -
# 4  Short offline       Completed without error       00%      1025         -
# 5  Short offline       Completed without error       00%      1001         -
# 6  Extended offline    Completed without error       00%       979         -
# 7  Short offline       Completed without error       00%       953         -
# 8  Short offline       Completed without error       00%       929         -
# 9  Short offline       Completed without error       00%       905         -
#10  Short offline       Completed without error       00%       881         -
#11  Short offline       Completed without error       00%       857         -
#12  Short offline       Completed without error       00%       833         -
#13  Extended offline    Completed without error       00%       811         -
#14  Short offline       Completed without error       00%       785         -
#15  Short offline       Completed without error       00%       761         -
#16  Short offline       Completed without error       00%       737         -
#17  Short offline       Completed without error       00%       713         -
#18  Short offline       Completed without error       00%       689         -
#19  Short offline       Completed without error       00%       665         -
#20  Extended offline    Completed without error       00%       643         -
#21  Short offline       Completed without error       00%       617         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
The Planet: dedicated and managed hosting, cloud storage, colocation
Stay online with enterprise data centers and the best network in the business
Choose flexible plans and management services without long-term contracts
Personal 24x7 support from experience hosting pros just a phone call away.
http://p.sf.net/sfu/theplanet-com
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to