Attached is an entry for a missing disk, it's a 2.5" SATA hitachi.

Dump is from a couple of revs back smartmontools, but it seems, looking at the code, that this disk is missing from the very latest smartmontools.

Excellent software BTW!

smartctl version 5.37 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     Hitachi HTE723232L9A360
Serial Number:    081011FC1403NQG606PC
Firmware Version: FC4OC30F
User Capacity:    320,072,933,376 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Not recognized. Minor revision code: 0x42
Local Time is:    Thu Feb 11 15:20:11 2010 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 247) Self-test routine in progress...
                                        70% of test remaining.
Total time to complete Offline 
data collection:                 ( 645) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  96) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   062    Pre-fail  Always       
-       0
  2 Throughput_Performance  0x0005   100   100   040    Pre-fail  Offline      
-       0
  3 Spin_Up_Time            0x0007   253   253   033    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       
-       21
  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0005   100   100   040    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0012   092   092   000    Old_age   Always       
-       3781
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       21
191 G-Sense_Error_Rate      0x000a   100   100   000    Old_age   Always       
-       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       21
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       
-       179
194 Temperature_Celsius     0x0002   211   211   000    Old_age   Always       
-       26 (Lifetime Min/Max 21/34)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       6
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       
-       1
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       
-       0
223 Load_Retry_Count        0x000a   100   100   000    Old_age   Always       
-       0

SMART Error Log Version: 1
ATA Error Count: 439 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 439 occurred at disk power-on lifetime: 3376 hours (140 days + 16 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 d5 8b b7 7c e0  Error: UNC 213 sectors at LBA = 0x007cb78b = 8173451

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 f0 70 b7 7c e0 08      00:04:39.000  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:35.300  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:31.400  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:27.600  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:23.700  READ DMA EXT

Error 438 occurred at disk power-on lifetime: 3376 hours (140 days + 16 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 d5 8b b7 7c e0  Error: UNC 213 sectors at LBA = 0x007cb78b = 8173451

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 f0 70 b7 7c e0 08      00:04:35.300  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:31.400  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:27.600  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:23.700  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:19.700  READ DMA EXT

Error 437 occurred at disk power-on lifetime: 3376 hours (140 days + 16 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 d5 8b b7 7c e0  Error: UNC 213 sectors at LBA = 0x007cb78b = 8173451

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 f0 70 b7 7c e0 08      00:04:31.400  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:27.600  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:23.700  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:19.700  READ DMA EXT
  25 00 f2 6e b7 7c e0 08      00:04:15.700  READ DMA EXT

Error 436 occurred at disk power-on lifetime: 3376 hours (140 days + 16 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 d5 8b b7 7c e0  Error: UNC 213 sectors at LBA = 0x007cb78b = 8173451

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 f0 70 b7 7c e0 08      00:04:27.600  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:23.700  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:19.700  READ DMA EXT
  25 00 f2 6e b7 7c e0 08      00:04:15.700  READ DMA EXT
  25 00 f2 6e b7 7c e0 08      00:04:11.900  READ DMA EXT

Error 435 occurred at disk power-on lifetime: 3376 hours (140 days + 16 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 d5 8b b7 7c e0  Error: UNC 213 sectors at LBA = 0x007cb78b = 8173451

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 f0 70 b7 7c e0 08      00:04:23.700  READ DMA EXT
  25 00 f0 70 b7 7c e0 08      00:04:19.700  READ DMA EXT
  25 00 f2 6e b7 7c e0 08      00:04:15.700  READ DMA EXT
  25 00 f2 6e b7 7c e0 08      00:04:11.900  READ DMA EXT
  25 00 f2 6e b7 7c e0 08      00:04:08.100  READ DMA EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Extended offline    Completed: read failure       90%      3376         
33471361
# 2  Short offline       Completed without error       00%      3376         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


--
Lawrence Manning
Lead Developer

SmoothWall Ltd
1 John Charles Way
Leeds LS12 6QA
United Kingdom

1 800 959 3760     (USA, Canada and North America)
0870 1 999 500     (United Kingdom)
+44 870 1 999 500  (All other countries)

SmoothWall is registered in England: 4298247

This email and any attachments transmitted with it are confidential to the intended recipient(s) and may not be communicated to any other person or published by any means without the permission of SmoothWall Limited. Any opinions stated in this message are solely those of the author. See: http://smoothwall.net/company/email.php for the full text of this notice.

------------------------------------------------------------------------------
SOLARIS 10 is the OS for Data Centers - provides features such as DTrace,
Predictive Self Healing and Award Winning ZFS. Get Solaris 10 NOW
http://p.sf.net/sfu/solaris-dev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to