Please, could you add WD1600HLFS-75G6U1 device in database ?
It seems not distinguished than WD1500HLFS (present in database) on Western Digital web site :
<http://support.wdc.com/product/download.asp?modelno=WD1600HLFS-75G6U1&x=3&y=11>

Thanks
Luc.

*******************************************************************
here, smartctl result :

smartctl -a /dev/sda
smartctl 5.40 2010-02-03 r3060 [i686-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD1600HLFS-75G6U1
Serial Number:    WD-WX20C7935990
Firmware Version: 04.04V03
User Capacity:    160 000 000 000 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Tue Feb  9 12:05:57 2010 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.

General SMART Values:
Offline data collection status:  (0x84) Offline data collection activity
was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 73) The previous self-test completed having a test element that failed and the test
                                       element that failed is not known.
Total time to complete Offline
data collection:                 (2700) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
                                       Suspend Offline collection upon new
                                       command.
                                       Offline surface scan supported.
                                       Self-test supported.
                                       Conveyance Self-test supported.
                                       Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                       power-saving mode.
                                       Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                       General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  36) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.
SCT capabilities:              (0x303f) SCT Status supported.
                                       SCT Feature Control supported.
                                       SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 001 001 051 Pre-fail Always FAILING_NOW 18241 3 Spin_Up_Time 0x0003 200 200 021 Pre-fail Always - 2958 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 15 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x000e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 977 10 Spin_Retry_Count 0x0012 100 253 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0012 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 15 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 10 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 15 194 Temperature_Celsius 0x0022 117 114 000 Old_age Always - 30 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0 240 Head_Flying_Hours 0x0032 099 099 000 Old_age Always - 941 241 Total_LBAs_Written 0x0032 200 200 000 Old_age Always - 105937104 242 Total_LBAs_Read 0x0032 200 200 000 Old_age Always - 27350975

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed: unknown failure 90% 976 - # 2 Short offline Completed: unknown failure 90% 302 - # 3 Extended offline Completed: unknown failure 90% 287 - # 4 Extended offline Completed: unknown failure 90% 287 - # 5 Extended offline Completed: unknown failure 90% 210 - # 6 Short offline Completed without error 00% 0 -

SMART Selective self-test log data structure revision number 1
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
   1        0        0  Not_testing
   2        0        0  Not_testing
   3        0        0  Not_testing
   4        0        0  Not_testing
   5        0        0  Not_testing
Selective self-test flags (0x0):
 After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

Attachment: smime.p7s
Description: S/MIME Cryptographic Signature

------------------------------------------------------------------------------
SOLARIS 10 is the OS for Data Centers - provides features such as DTrace,
Predictive Self Healing and Award Winning ZFS. Get Solaris 10 NOW
http://p.sf.net/sfu/solaris-dev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to