Please, could you add WD1600HLFS-75G6U1 device in database ?It seems not distinguished than WD1500HLFS (present in database) on Western Digital web site :
<http://support.wdc.com/product/download.asp?modelno=WD1600HLFS-75G6U1&x=3&y=11>
Thanks Luc. ******************************************************************* here, smartctl result : smartctl -a /dev/sda smartctl 5.40 2010-02-03 r3060 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: WDC WD1600HLFS-75G6U1 Serial Number: WD-WX20C7935990 Firmware Version: 04.04V03 User Capacity: 160 000 000 000 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Tue Feb 9 12:05:57 2010 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. See vendor-specific Attribute list for failed Attributes. General SMART Values: Offline data collection status: (0x84) Offline data collection activitywas suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 73) The previous self-test completed having a test element that failed and the test
element that failed is not known. Total time to complete Offline data collection: (2700) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate.Auto Offline data collection on/off support.
Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 36) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds:ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 001 001 051 Pre-fail Always FAILING_NOW 18241 3 Spin_Up_Time 0x0003 200 200 021 Pre-fail Always - 2958 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 15 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x000e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 977 10 Spin_Retry_Count 0x0012 100 253 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0012 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 15 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 10 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 15 194 Temperature_Celsius 0x0022 117 114 000 Old_age Always - 30 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0 240 Head_Flying_Hours 0x0032 099 099 000 Old_age Always - 941 241 Total_LBAs_Written 0x0032 200 200 000 Old_age Always - 105937104 242 Total_LBAs_Read 0x0032 200 200 000 Old_age Always - 27350975
SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed: unknown failure 90% 976 - # 2 Short offline Completed: unknown failure 90% 302 - # 3 Extended offline Completed: unknown failure 90% 287 - # 4 Extended offline Completed: unknown failure 90% 287 - # 5 Extended offline Completed: unknown failure 90% 210 - # 6 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
smime.p7s
Description: S/MIME Cryptographic Signature
------------------------------------------------------------------------------ SOLARIS 10 is the OS for Data Centers - provides features such as DTrace, Predictive Self Healing and Award Winning ZFS. Get Solaris 10 NOW http://p.sf.net/sfu/solaris-dev2dev