Please add old  Seagate ST31720A   to the Smart database.
smartctl -a  -T verypermissive output is attached to this mail.

More sample outputs, pictures and drive specifiation can be found on

http://mitglied.multimania.de/jenderek/verkauf/harddisc/Seagate/ST31720A/

Best regards,

Jörg
-- 
Jörg Jenderek   email:  joerg.jen.der.ek (at) gmx.net
Germany         PGP:    B9FE A356 283E 0048 6389  18BF AFF2 B1C9 421A D4D6
smartctl 5.39.1 2010-01-28 r3054 [i686-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     ST31720A
Serial Number:    VA040596
Firmware Version: 0.62
User Capacity:    1,704,665,088 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   2
ATA Standard is:  Not recognized. Minor revision code: 0xffff
Local Time is:    Fri Feb  5 18:33:38 2010 CET
SMART is only available in ATA Version 3 Revision 3 or greater.
We will try to proceed in spite of this.
SMART support is: Ambiguous - ATA IDENTIFY DEVICE words 85-87 don't show if 
SMART is enabled.
                  Checking to be sure by trying SMART RETURN STATUS command.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Total time to complete Offline 
data collection:                 (   0) seconds.
Offline data collection
capabilities:                    (0x00)         Offline data collection not 
supported.
SMART capabilities:            (0x0002) Does not save SMART data before
                                        entering power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging NOT supported.
                                        No General Purpose Logging support.

SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000a   101   099   000    Old_age   Always       
-       31273852
  3 Spin_Up_Time            0x0006   096   094   000    Old_age   Always       
-       4
  4 Start_Stop_Count        0x0013   100   100   020    Pre-fail  Always       
-       462
  5 Reallocated_Sector_Ct   0x0013   100   100   036    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   050   046   030    Pre-fail  Always       
-       412328200262
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0013   100   100   020    Pre-fail  Always       
-       367

Warning: device does not support Error Logging
Error SMART Error Log Read failed: Input/output error
Smartctl: SMART Error Log Read Failed
Warning: device does not support Self Test Logging
Error SMART Error Self-Test Log Read failed: Input/output error
Smartctl: SMART Self Test Log Read Failed
Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------
Download Intel® Parallel Studio Eval
Try the new software tools for yourself. Speed compiling, find bugs
proactively, and fine-tune applications for parallel performance.
See why Intel Parallel Studio got high marks during beta.
http://p.sf.net/sfu/intel-sw-dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to