Seems to be missing a lot of SMART attributes that the older Indilinx
drives have.  See attached for smartctl -a output.

-Dave
smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     OCZ VERTEX-PLUS
Serial Number:    77AFCR2LP5UK72L4LJZ6
Firmware Version: 3.55
User Capacity:    60,022,480,896 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Thu Oct 27 16:24:42 2011 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 249) Self-test routine in progress...
                                        90% of test remaining.
Total time to complete Offline 
data collection:                 (   0) seconds.
Offline data collection
capabilities:                    (0x1d) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging NOT supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   0) minutes.
Extended self-test routine
recommended polling time:        (   0) minutes.

SMART Attributes Data Structure revision number: 18
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0000   005   000   000    Old_age   Offline      
-       5
  3 Spin_Up_Time            0x0000   100   100   000    Old_age   Offline      
-       0
  4 Start_Stop_Count        0x0000   100   100   000    Old_age   Offline      
-       0
  5 Reallocated_Sector_Ct   0x0000   100   100   000    Old_age   Offline      
-       0
  9 Power_On_Hours          0x0000   100   100   000    Old_age   Offline      
-       1298
 12 Power_Cycle_Count       0x0000   100   100   000    Old_age   Offline      
-       9
232 Available_Reservd_Space 0x0000   100   100   000    Old_age   Offline      
-       7830
233 Media_Wearout_Indicator 0x0000   100   000   000    Old_age   Offline      
-       100

Warning: device does not support Error Logging
Warning! SMART ATA Error Log Structure error: invalid SMART checksum.
SMART Error Log Version: 1
No Errors Logged

Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------