Please add a TOSHIBA MK2556GSYF to smartmontools.

Thanks,

Simon
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-3.1.1-1.fc16.x86_64] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     TOSHIBA MK2556GSYF
Serial Number:    Z0AIT5F4T
LU WWN Device Id: 5 000039 2f18829c3
Firmware Version: LJ001D
User Capacity:    250,059,350,016 bytes [250 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Mon Nov 14 09:37:08 2011 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 246) Self-test routine in progress...
                                        60% of test remaining.
Total time to complete Offline 
data collection:                (  120) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  62) minutes.
SCT capabilities:              (0x0039) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 128
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0027   100   100   001    Pre-fail  Always       
-       1356
  5 Reallocated_Sector_Ct   0x0033   100   100   050    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0032   098   098   000    Old_age   Always       
-       57815
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       1254
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       
-       945
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       72
193 Load_Cycle_Count        0x0032   096   096   000    Old_age   Always       
-       47427
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       
-       41 (Min/Max 14/67)
199 UDMA_CRC_Error_Count    0x0032   100   100   000    Old_age   Always       
-       10648066
200 Multi_Zone_Error_Rate   0x0032   100   100   000    Old_age   Always       
-       30170861
240 Head_Flying_Hours       0x0032   099   099   000    Old_age   Always       
-       37588
241 Total_LBAs_Written      0x0032   100   100   000    Old_age   Always       
-       91374947870
242 Total_LBAs_Read         0x0032   100   100   000    Old_age   Always       
-       106113270048
254 Free_Fall_Sensor        0x0032   100   100   000    Old_age   Always       
-       45

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%       963         -
# 2  Short offline       Aborted by host               60%       594         -
# 3  Short offline       Completed without error       00%       587         -
# 4  Short offline       Completed without error       00%       587         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------