Below are the URL and the smartctl output for the Seagate Constellation ES SATA ST1000NM0011 3.5" SATA 6.0 Gbps HDD http://www.seagate.com/ww/v/index.jsp?vgnextoid=47eb82e80ee5e210VgnVCM1000001a48090aRCRD&vgnextchannel=f424072516d8c010VgnVCM100000dd04090aRCRD&locale=en-GB&reqPage=Support
# smartctl -i -r ioctl,2 /dev/sda smartctl 5.43 2011-10-27 r3462M [x86_64-linux-2.6.18-238.19.1.el5] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net [inquiry: 12 00 00 00 24 00 ] scsi_status=0x0, host_status=0x0, driver_status=0x0 info=0x0 duration=0 milliseconds resid=0 Incoming data, len=36: 00 00 00 05 02 5b 00 00 00 41 54 41 20 20 20 20 20 10 53 54 31 30 30 30 4e 4d 30 30 31 31 20 20 20 20 20 53 4e 30 32 status=0x0 [ata pass-through(16): 85 08 0e 00 00 00 01 00 00 00 00 00 00 00 ec 00 ] scsi_status=0x0, host_status=0x0, driver_status=0x0 info=0x0 duration=0 milliseconds resid=0 Incoming data, len=512 [only first 256 bytes shown]: 00 5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 10 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 20 31 5a 30 4e 41 33 59 35 00 00 00 00 04 00 4e 53 30 32 30 20 20 20 20 54 53 30 31 30 30 4d 4e 30 30 40 31 31 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 60 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 70 3f 00 10 fc fb 00 10 00 ff ff ff 0f 00 00 07 00 80 03 00 78 00 78 00 78 00 78 00 00 00 00 00 00 00 90 00 00 00 00 00 00 1f 00 0e 85 04 00 48 00 40 00 a0 f0 01 29 00 6b 34 01 7d 63 41 69 34 01 bc 63 41 b0 7f 40 48 00 48 00 00 00 fe ff 00 00 00 fe 00 00 c0 00 00 00 00 00 00 00 00 b0 6d 70 74 00 00 00 00 d0 00 00 00 00 00 40 00 00 00 50 00 c5 d1 35 00 7f e0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 9e 40 f0 1c 40 00 00 00 00 00 00 00 00 00 00 00 00 00 00 status=0x0 REPORT-IOCTL: Device=/dev/sda Command=IDENTIFY DEVICE Input: FR=...., SC=0x01, LL=...., LM=...., LH=...., DEV=...., CMD=0xec IN [ata pass-through(16): 85 08 0e 00 00 00 01 00 00 00 00 00 00 00 ec 00 ] scsi_status=0x0, host_status=0x0, driver_status=0x0 info=0x0 duration=1 milliseconds resid=0 Incoming data, len=512 [only first 256 bytes shown]: 00 5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 10 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 20 31 5a 30 4e 41 33 59 35 00 00 00 00 04 00 4e 53 30 32 30 20 20 20 20 54 53 30 31 30 30 4d 4e 30 30 40 31 31 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 60 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 70 3f 00 10 fc fb 00 10 00 ff ff ff 0f 00 00 07 00 80 03 00 78 00 78 00 78 00 78 00 00 00 00 00 00 00 90 00 00 00 00 00 00 1f 00 0e 85 04 00 48 00 40 00 a0 f0 01 29 00 6b 34 01 7d 63 41 69 34 01 bc 63 41 b0 7f 40 48 00 48 00 00 00 fe ff 00 00 00 fe 00 00 c0 00 00 00 00 00 00 00 00 b0 6d 70 74 00 00 00 00 d0 00 00 00 00 00 40 00 00 00 50 00 c5 d1 35 00 7f e0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 9e 40 f0 1c 40 00 00 00 00 00 00 00 00 00 00 00 00 00 00 status=0x0 REPORT-IOCTL: Device=/dev/sda Command=IDENTIFY DEVICE returned 0 ===== [IDENTIFY DEVICE] DATA START (BASE-16) ===== 000-015: 5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 |Z..?7.......?...| 016-031: 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 |.... | 032-047: 31 5a 30 4e 41 33 59 35 00 00 00 00 04 00 4e 53 |1Z0NA3Y5......NS| 048-063: 32 30 20 20 20 20 54 53 30 31 30 30 4d 4e 30 30 |20 TS0100MN00| 064-079: 31 31 20 20 20 20 20 20 20 20 20 20 20 20 20 20 |11 | 080-095: 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 | ..| 096-111: 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 |.@./.@.......?..| 112-127: 3f 00 10 fc fb 00 10 00 ff ff ff 0f 00 00 07 00 |?...............| 128-143: 03 00 78 00 78 00 78 00 78 00 00 00 00 00 00 00 |..x.x.x.x.......| 144-159: 00 00 00 00 00 00 1f 00 0e 85 04 00 48 00 40 00 |............H.@.| 160-175: f0 01 29 00 6b 34 01 7d 63 41 69 34 01 bc 63 41 |..).k4.}cAi4..cA| 176-191: 7f 40 48 00 48 00 00 00 fe ff 00 00 00 fe 00 00 |.@H.H...........| 192-207: 00 00 00 00 00 00 00 00 b0 6d 70 74 00 00 00 00 |.........mpt....| 208-223: 00 00 00 00 00 40 00 00 00 50 00 c5 d1 35 00 7f |.....@...P...5..| 224-239: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 9e 40 |...............@| 240-255: 1c 40 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |.@..............| 256-271: 21 00 b0 6d 70 74 b0 6d 70 74 20 20 02 00 40 01 |!..mpt.mpt ..@.| 272-287: 00 01 00 50 06 3c 0a 3c 00 00 3c 00 00 00 08 00 |...P.<.<..<.....| 288-303: 00 00 00 00 ef 01 80 02 00 00 70 00 08 00 00 00 |..........p.....| 304-319: 00 00 00 00 00 00 00 00 00 00 00 00 00 65 40 b8 |.............e@.| 320-335: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| 336-351: 02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| 352-367: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| 368-383: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| 384-399: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| 400-415: 00 00 00 00 00 00 00 00 00 00 00 00 bd 10 00 00 |................| 416-431: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| 432-447: 00 00 22 1c 00 00 00 00 00 00 00 00 20 10 00 00 |.."......... ...| 448-463: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| 464-479: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| 480-495: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| 496-511: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 a5 71 |...............q| ===== [IDENTIFY DEVICE] DATA END (512 Bytes) ===== === START OF INFORMATION SECTION === Device Model: ST1000NM0011 Serial Number: Z1N03A5Y LU WWN Device Id: 5 000c50 035d17f00 Firmware Version: SN02 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Thu Nov 17 10:44:40 2011 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled # smartctl -a /dev/sda smartctl 5.43 2011-10-27 r3462M [x86_64-linux-2.6.18-238.19.1.el5] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: ST1000NM0011 Serial Number: Z1N03A5Y LU WWN Device Id: 5 000c50 035d17f00 Firmware Version: SN02 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Thu Nov 17 10:44:56 2011 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 249) Self-test routine in progress... 90% of test remaining. Total time to complete Offline data collection: ( 114) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 150) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x10bd) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 081 075 044 Pre-fail Always - 143000147 3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 6 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 100 253 030 Pre-fail Always - 371021 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 16 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 6 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 072 049 045 Old_age Always - 28 (Min/Max 24/28) 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 4 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 6 194 Temperature_Celsius 0x0022 028 051 000 Old_age Always - 28 (0 21 0 0 0) 195 Hardware_ECC_Recovered 0x001a 117 100 000 Old_age Always - 143000147 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Self-test routine in progress 90% 16 - # 2 Extended offline Interrupted (host reset) 90% 16 - # 3 Extended offline Completed without error 00% 12 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. # smartctl -x /dev/sda smartctl 5.43 2011-10-27 r3462M [x86_64-linux-2.6.18-238.19.1.el5] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: ST1000NM0011 Serial Number: Z1N03A5Y LU WWN Device Id: 5 000c50 035d17f00 Firmware Version: SN02 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Thu Nov 17 10:45:12 2011 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 249) Self-test routine in progress... 90% of test remaining. Total time to complete Offline data collection: ( 114) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 150) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x10bd) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 081 075 044 - 143005522 3 Spin_Up_Time PO---- 097 097 000 - 0 4 Start_Stop_Count -O--CK 100 100 020 - 6 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0 7 Seek_Error_Rate POSR-- 100 253 030 - 371123 9 Power_On_Hours -O--CK 100 100 000 - 16 10 Spin_Retry_Count PO--C- 100 100 097 - 0 12 Power_Cycle_Count -O--CK 100 100 020 - 6 184 End-to-End_Error -O--CK 100 100 099 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 100 000 - 0 189 High_Fly_Writes -O-RCK 100 100 000 - 0 190 Airflow_Temperature_Cel -O---K 072 049 045 - 28 (Min/Max 24/28) 191 G-Sense_Error_Rate -O--CK 100 100 000 - 0 192 Power-Off_Retract_Count -O--CK 100 100 000 - 4 193 Load_Cycle_Count -O--CK 100 100 000 - 6 194 Temperature_Celsius -O---K 028 051 000 - 28 (0 21 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 117 100 000 - 143005522 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----C- 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] GP/S Log at address 0x00 has 1 sectors [Log Directory] SMART Log at address 0x01 has 1 sectors [Summary SMART error log] SMART Log at address 0x02 has 5 sectors [Comprehensive SMART error log] GP Log at address 0x03 has 5 sectors [Ext. Comprehensive SMART error log] SMART Log at address 0x06 has 1 sectors [SMART self-test log] GP Log at address 0x07 has 1 sectors [Extended self-test log] SMART Log at address 0x09 has 1 sectors [Selective self-test log] GP Log at address 0x10 has 1 sectors [NCQ Command Error log] GP Log at address 0x11 has 1 sectors [SATA Phy Event Counters] GP/S Log at address 0x12 has 1 sectors [Reserved for Serial ATA] GP Log at address 0x21 has 1 sectors [Write stream error log] GP Log at address 0x22 has 1 sectors [Read stream error log] GP/S Log at address 0x80 has 16 sectors [Host vendor specific log] GP/S Log at address 0x81 has 16 sectors [Host vendor specific log] GP/S Log at address 0x82 has 16 sectors [Host vendor specific log] GP/S Log at address 0x83 has 16 sectors [Host vendor specific log] GP/S Log at address 0x84 has 16 sectors [Host vendor specific log] GP/S Log at address 0x85 has 16 sectors [Host vendor specific log] GP/S Log at address 0x86 has 16 sectors [Host vendor specific log] GP/S Log at address 0x87 has 16 sectors [Host vendor specific log] GP/S Log at address 0x88 has 16 sectors [Host vendor specific log] GP/S Log at address 0x89 has 16 sectors [Host vendor specific log] GP/S Log at address 0x8a has 16 sectors [Host vendor specific log] GP/S Log at address 0x8b has 16 sectors [Host vendor specific log] GP/S Log at address 0x8c has 16 sectors [Host vendor specific log] GP/S Log at address 0x8d has 16 sectors [Host vendor specific log] GP/S Log at address 0x8e has 16 sectors [Host vendor specific log] GP/S Log at address 0x8f has 16 sectors [Host vendor specific log] GP/S Log at address 0x90 has 16 sectors [Host vendor specific log] GP/S Log at address 0x91 has 16 sectors [Host vendor specific log] GP/S Log at address 0x92 has 16 sectors [Host vendor specific log] GP/S Log at address 0x93 has 16 sectors [Host vendor specific log] GP/S Log at address 0x94 has 16 sectors [Host vendor specific log] GP/S Log at address 0x95 has 16 sectors [Host vendor specific log] GP/S Log at address 0x96 has 16 sectors [Host vendor specific log] GP/S Log at address 0x97 has 16 sectors [Host vendor specific log] GP/S Log at address 0x98 has 16 sectors [Host vendor specific log] GP/S Log at address 0x99 has 16 sectors [Host vendor specific log] GP/S Log at address 0x9a has 16 sectors [Host vendor specific log] GP/S Log at address 0x9b has 16 sectors [Host vendor specific log] GP/S Log at address 0x9c has 16 sectors [Host vendor specific log] GP/S Log at address 0x9d has 16 sectors [Host vendor specific log] GP/S Log at address 0x9e has 16 sectors [Host vendor specific log] GP/S Log at address 0x9f has 16 sectors [Host vendor specific log] GP/S Log at address 0xa1 has 20 sectors [Device vendor specific log] GP Log at address 0xa2 has 4496 sectors [Device vendor specific log] GP/S Log at address 0xa8 has 129 sectors [Device vendor specific log] GP/S Log at address 0xa9 has 1 sectors [Device vendor specific log] GP Log at address 0xb0 has 5176 sectors [Device vendor specific log] GP Log at address 0xb6 has 1918 sectors [Device vendor specific log] GP Log at address 0xbd has 252 sectors [Device vendor specific log] GP Log at address 0xbe has 65535 sectors [Device vendor specific log] GP Log at address 0xbf has 65535 sectors [Device vendor specific log] GP/S Log at address 0xe0 has 1 sectors [SCT Command/Status] GP/S Log at address 0xe1 has 1 sectors [SCT Data Transfer] SMART Extended Comprehensive Error Log Version: 1 (5 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Self-test routine in progress 90% 16 - # 2 Extended offline Interrupted (host reset) 90% 16 - # 3 Extended offline Completed without error 00% 12 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 522 (0x020a) SCT Support Level: 1 Device State: Active (0) Current Temperature: 28 Celsius Power Cycle Min/Max Temperature: 24/28 Celsius Lifetime Min/Max Temperature: 21/51 Celsius Under/Over Temperature Limit Count: 0/6 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/ 0 Celsius Min/Max Temperature Limit: 0/ 0 Celsius Temperature History Size (Index): 128 (113) Index Estimated Time Temperature Celsius 114 2011-11-16 13:30 ? - ... ..( 12 skipped). .. - 127 2011-11-16 15:40 ? - 0 2011-11-16 15:50 51 ******************************** 1 2011-11-16 16:00 ? - 2 2011-11-16 16:10 21 ** 3 2011-11-16 16:20 ? - 4 2011-11-16 16:30 24 ***** 5 2011-11-16 16:40 ? - 6 2011-11-16 16:50 27 ******** 7 2011-11-16 17:00 ? - 8 2011-11-16 17:10 23 **** 9 2011-11-16 17:20 26 ******* 10 2011-11-16 17:30 27 ******** 11 2011-11-16 17:40 ? - 12 2011-11-16 17:50 25 ****** 13 2011-11-16 18:00 26 ******* 14 2011-11-16 18:10 27 ******** 15 2011-11-16 18:20 28 ********* ... ..( 5 skipped). .. ********* 21 2011-11-16 19:20 28 ********* 22 2011-11-16 19:30 27 ******** ... ..( 3 skipped). .. ******** 26 2011-11-16 20:10 27 ******** 27 2011-11-16 20:20 26 ******* 28 2011-11-16 20:30 27 ******** ... ..( 17 skipped). .. ******** 46 2011-11-16 23:30 27 ******** 47 2011-11-16 23:40 26 ******* 48 2011-11-16 23:50 26 ******* 49 2011-11-17 00:00 27 ******** ... ..( 2 skipped). .. ******** 52 2011-11-17 00:30 27 ******** 53 2011-11-17 00:40 26 ******* 54 2011-11-17 00:50 27 ******** 55 2011-11-17 01:00 27 ******** 56 2011-11-17 01:10 26 ******* ... ..( 2 skipped). .. ******* 59 2011-11-17 01:40 26 ******* 60 2011-11-17 01:50 25 ****** ... ..( 5 skipped). .. ****** 66 2011-11-17 02:50 25 ****** 67 2011-11-17 03:00 26 ******* ... ..( 3 skipped). .. ******* 71 2011-11-17 03:40 26 ******* 72 2011-11-17 03:50 25 ****** 73 2011-11-17 04:00 25 ****** 74 2011-11-17 04:10 26 ******* ... ..( 3 skipped). .. ******* 78 2011-11-17 04:50 26 ******* 79 2011-11-17 05:00 25 ****** ... ..( 15 skipped). .. ****** 95 2011-11-17 07:40 25 ****** 96 2011-11-17 07:50 26 ******* ... ..( 9 skipped). .. ******* 106 2011-11-17 09:30 26 ******* 107 2011-11-17 09:40 ? - 108 2011-11-17 09:50 24 ***** 109 2011-11-17 10:00 24 ***** 110 2011-11-17 10:10 27 ******** 111 2011-11-17 10:20 27 ******** 112 2011-11-17 10:30 28 ********* 113 2011-11-17 10:40 28 ********* SCT Error Recovery Control: Read: 100 (10.0 seconds) Write: 100 (10.0 seconds) SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 15 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS ------------------------------------------------------------------------------ All the data continuously generated in your IT infrastructure contains a definitive record of customers, application performance, security threats, fraudulent activity, and more. Splunk takes this data and makes sense of it. IT sense. And common sense. http://p.sf.net/sfu/splunk-novd2d _______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database