Hi,
I just realised that this HDD isn't included in the smartmontools-db (checked
current svn revision 3502): Seagate ST31000525SV
#9 is Power on time in HOURS, 2760 = 115 days, that perfectly makes sense (it's
a 24/7 System)
I'm concerned about #1 Raw_Read_Error_Rate, #7 Seek_Error_Rate, #195
Hardware_ECC_Recovered. All these Values (raw) increase continously, but
I'm now sure if it's that's an artefact (FAQ:''if any of the Attributes are
behaving strangely'') or not.
Thank you very much,
regards,
Manuel Presnitz.
--
Empfehlen Sie GMX DSL Ihren Freunden und Bekannten und wir
belohnen Sie mit bis zu 50,- Euro! https://freundschaftswerbung.gmx.de
# smartctl --all /dev/s
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.25.16-0.1-default] (local
build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: ST31000525SV
Serial Number: 6VP4SCWW
LU WWN Device Id: 5 000c50 027e7cfe7
Firmware Version: CV12
User Capacity: 1.000.204.886.016 bytes [1,00 TB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 4
Local Time is: Fri Jan 27 12:35:53 2012 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 600) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 174) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x10bb) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 108 099 006 Pre-fail Always
- 19619581
3 Spin_Up_Time 0x0003 098 098 000 Pre-fail Always
- 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always
- 9
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always
- 0
7 Seek_Error_Rate 0x000f 075 060 030 Pre-fail Always
- 37015910
9 Power_On_Hours 0x0032 097 097 000 Old_age Always
- 2761
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always
- 4
184 End-to-End_Error 0x0032 100 100 099 Old_age Always
- 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always
- 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always
- 0
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always
- 0
190 Airflow_Temperature_Cel 0x0022 065 061 045 Old_age Always
- 35 (Min/Max 32/39)
194 Temperature_Celsius 0x0022 035 040 000 Old_age Always
- 35 (0 27 0 0 0)
195 Hardware_ECC_Recovered 0x001a 045 038 000 Old_age Always
- 19619581
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 2761 -
# 2 Short offline Completed without error 00% 22 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Try before you buy = See our experts in action!
The most comprehensive online learning library for Microsoft developers
is just $99.99! Visual Studio, SharePoint, SQL - plus HTML5, CSS3, MVC3,
Metro Style Apps, more. Free future releases when you subscribe now!
http://p.sf.net/sfu/learndevnow-dev2
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database