smartctl 5.42 2011-10-20 r3458 [i686-w64-mingw32-win7] (sf-win32-5.42-1)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG HN-M101MBB
Serial Number: S2RXJ9AB900765
LU WWN Device Id: 5 0024e9 206105f8b
Firmware Version: 2AR10001
User Capacity: 1.000.204.886.016 bytes [1,00 TB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 6
Local Time is: Tue Jan 31 13:23:33 2012 MZ
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 121) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: (14160) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 236) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always
- 3601
2 Throughput_Performance 0x0026 252 252 000 Old_age Always
- 0
3 Spin_Up_Time 0x0023 086 086 025 Pre-fail Always
- 4456
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 239
5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always
- 0
8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 886
10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always
- 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always
- 8
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 226
181 Program_Fail_Cnt_Total 0x0022 099 099 000 Old_age Always
- 42178949
191 G-Sense_Error_Rate 0x0022 252 252 000 Old_age Always
- 0
192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always
- 0
194 Temperature_Celsius 0x0002 064 061 000 Old_age Always
- 33 (Min/Max 20/39)
195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always
- 0
196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always
- 12
198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always
- 0
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always
- 8
225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always
- 1916
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed: read failure 90% 886
209934304
# 2 Short offline Completed: read failure 90% 863
209934304
# 3 Short offline Completed: read failure 90% 836
209934304
# 4 Short offline Completed: read failure 90% 766
209934304
# 5 Extended offline Completed: read failure 90% 514
253994160
# 6 Short offline Completed: read failure 90% 513
253994160
# 7 Short offline Completed: read failure 90% 455
253994160
# 8 Short offline Aborted by host 80% 44 -
# 9 Short offline Aborted by host 90% 24 -
#10 Short offline Completed without error 00% 0 -
Note: selective self-test log revision number (0) not 1 implies that no
selective self-test has ever been run
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been
run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed_read_failure [90% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Try before you buy = See our experts in action!
The most comprehensive online learning library for Microsoft developers
is just $99.99! Visual Studio, SharePoint, SQL - plus HTML5, CSS3, MVC3,
Metro Style Apps, more. Free future releases when you subscribe now!
http://p.sf.net/sfu/learndevnow-dev2
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database