Kingston HYPER X 120GB via Seagate eSATAp cable.
The power-on hours are misreported, I am sending two attachments, if
you can figure out the way they are encoded.
The drive is new, just arrived, connected first time, so the first
reading must be close to 0 (given it was tested, that is why 3
power-on cycles were logged)

Cheers,
Kalin.
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-3.0.4] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     Seagate eSATA Cable
Serial Number:    2HC015KJ
LU WWN Device Id: 5 0026b7 21a112408
Firmware Version: 0110BBF0
User Capacity:    120,034,123,776 bytes [120 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ACS-2 revision 3
Local Time is:    Sun Jan 29 13:28:37 2012 JST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                ( 2097) seconds.
Offline data collection
capabilities:                    (0x7f) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  48) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x0021) SCT Status supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   120   120   050    Pre-fail  Always       
-       0
  5 Reallocated_Sector_Ct   0x0033   100   100   003    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       52776558133248
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       3
171 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       
-       0
172 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       
-       0
174 Unknown_Attribute       0x0030   000   000   000    Old_age   Offline      
-       1
177 Wear_Leveling_Count     0x0000   000   000   000    Old_age   Offline      
-       0
181 Program_Fail_Cnt_Total  0x0032   000   000   000    Old_age   Always       
-       0
182 Erase_Fail_Count_Total  0x0032   000   000   000    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
194 Temperature_Celsius     0x0022   028   029   000    Old_age   Always       
-       28 (Min/Max 20/29)
195 Hardware_ECC_Recovered  0x001c   100   100   000    Old_age   Offline      
-       0
196 Reallocated_Event_Count 0x0033   100   100   003    Pre-fail  Always       
-       0
201 Soft_Read_Error_Rate    0x001c   100   100   000    Old_age   Offline      
-       0
204 Soft_ECC_Correction     0x001c   100   100   000    Old_age   Offline      
-       0
230 Head_Amplitude          0x0013   100   100   000    Pre-fail  Always       
-       100
231 Temperature_Celsius     0x0013   100   100   010    Pre-fail  Always       
-       0
233 Media_Wearout_Indicator 0x0000   000   000   000    Old_age   Offline      
-       0
234 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       
-       0
241 Total_LBAs_Written      0x0032   000   000   000    Old_age   Always       
-       0
242 Total_LBAs_Read         0x0032   000   000   000    Old_age   Always       
-       0

SMART Error Log not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

smartctl 5.42 2011-10-20 r3458 [x86_64-linux-3.0.4] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     Seagate eSATA Cable
Serial Number:    2HC015KJ
LU WWN Device Id: 5 0026b7 21a112408
Firmware Version: 0110BBF0
User Capacity:    120,034,123,776 bytes [120 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ACS-2 revision 3
Local Time is:    Sun Jan 29 13:32:59 2012 JST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                ( 2097) seconds.
Offline data collection
capabilities:                    (0x7f) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  48) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x0021) SCT Status supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   120   120   050    Pre-fail  Always       
-       0
  5 Reallocated_Sector_Ct   0x0033   100   100   003    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       47502338293760
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       3
171 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       
-       0
172 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       
-       0
174 Unknown_Attribute       0x0030   000   000   000    Old_age   Offline      
-       1
177 Wear_Leveling_Count     0x0000   000   000   000    Old_age   Offline      
-       0
181 Program_Fail_Cnt_Total  0x0032   000   000   000    Old_age   Always       
-       0
182 Erase_Fail_Count_Total  0x0032   000   000   000    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
194 Temperature_Celsius     0x0022   029   029   000    Old_age   Always       
-       29 (Min/Max 20/29)
195 Hardware_ECC_Recovered  0x001c   100   100   000    Old_age   Offline      
-       0
196 Reallocated_Event_Count 0x0033   100   100   003    Pre-fail  Always       
-       0
201 Soft_Read_Error_Rate    0x001c   100   100   000    Old_age   Offline      
-       0
204 Soft_ECC_Correction     0x001c   100   100   000    Old_age   Offline      
-       0
230 Head_Amplitude          0x0013   100   100   000    Pre-fail  Always       
-       100
231 Temperature_Celsius     0x0013   100   100   010    Pre-fail  Always       
-       0
233 Media_Wearout_Indicator 0x0000   000   000   000    Old_age   Offline      
-       0
234 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       
-       0
241 Total_LBAs_Written      0x0032   000   000   000    Old_age   Always       
-       0
242 Total_LBAs_Read         0x0032   000   000   000    Old_age   Always       
-       0

SMART Error Log not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Try before you buy = See our experts in action!
The most comprehensive online learning library for Microsoft developers
is just $99.99! Visual Studio, SharePoint, SQL - plus HTML5, CSS3, MVC3,
Metro Style Apps, more. Free future releases when you subscribe now!
http://p.sf.net/sfu/learndevnow-dev2
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to