Hello,
Please find attached the data for a TOSHIBA MK3259GSX on a JMicron
bridge (sold as an LG external drive).
While the drive itself is in the database, the usbjmicron,x hint
should still be added for this bridge.
Thanks!
--
jimmy
# smartctl -a /dev/da0
smartctl 5.42 2011-10-20 r3458 [FreeBSD 9.0-STABLE amd64] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
/dev/da0: Unknown USB bridge [0x043e:0x70f1 (0x100)]
^^^^^^^^^^^^^
Smartctl: please specify device type with the -d option.
Use smartctl -h to get a usage summary
# smartctl -a /dev/da0 -d usbjmicron,x
smartctl 5.42 2011-10-20 r3458 [FreeBSD 9.0-STABLE amd64] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Toshiba 2.5" HDD MK..59GSXP (Adv. Format)
Device Model: TOSHIBA MK3259GSX
Serial Number: 30PEF8TPS
LU WWN Device Id: 5 000039 266e084e5
Firmware Version: GK003U
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Fri Feb 3 00:15:16 2012 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 249) Self-test routine in progress...
90% of test remaining.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 104) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always
- 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline
- 0
3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always
- 1722
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 918
5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always
- 0
7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always
- 0
8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline
- 0
9 Power_On_Hours 0x0032 097 097 000 Old_age Always
- 1482
10 Spin_Retry_Count 0x0033 118 100 030 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 918
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always
- 1
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 194
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always
- 4758
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always
- 42 (Min/Max 12/47)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always
- 1
220 Disk_Shift 0x0002 100 100 000 Old_age Always
- 83
222 Loaded_Hours 0x0032 098 098 000 Old_age Always
- 857
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always
- 0
224 Load_Friction 0x0022 100 100 000 Old_age Always
- 0
226 Load-in_Time 0x0026 100 100 000 Old_age Always
- 348
240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline
- 0
SMART Error Log Version: 1
ATA Error Count: 42 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 42 occurred at disk power-on lifetime: 1183 hours (49 days + 7 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 80 00 82 09 e4 Error: UNC 128 sectors at LBA = 0x04098200 = 67731968
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 80 00 82 09 e0 00 04:59:25.274 READ DMA EXT
25 00 80 80 81 09 e0 00 04:59:25.272 READ DMA EXT
25 00 80 00 81 09 e0 00 04:59:25.270 READ DMA EXT
25 00 80 80 80 09 e0 00 04:59:25.268 READ DMA EXT
25 00 80 00 80 09 e0 00 04:59:25.266 READ DMA EXT
Error 41 occurred at disk power-on lifetime: 1039 hours (43 days + 7 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 c1 e6 3f e0 Error: ICRC, ABRT 1 sectors at LBA = 0x003fe6c1 =
4187841
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
35 00 80 42 e6 3f e0 00 01:24:10.134 WRITE DMA EXT
35 00 80 c2 e5 3f e0 00 01:24:10.128 WRITE DMA EXT
35 00 80 42 e5 3f e0 00 01:24:10.122 WRITE DMA EXT
35 00 80 c2 e4 3f e0 00 01:24:10.117 WRITE DMA EXT
35 00 80 42 e4 3f e0 00 01:24:10.112 WRITE DMA EXT
Error 40 occurred at disk power-on lifetime: 861 hours (35 days + 21 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 80 00 44 09 e4 Error: UNC 128 sectors at LBA = 0x04094400 = 67716096
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 80 00 44 09 e0 00 01:40:29.383 READ DMA EXT
25 00 80 80 87 09 e0 00 01:40:29.381 READ DMA EXT
25 00 80 00 87 09 e0 00 01:40:29.373 READ DMA EXT
25 00 80 80 88 09 e0 00 01:40:29.371 READ DMA EXT
25 00 80 00 88 09 e0 00 01:40:29.365 READ DMA EXT
Error 39 occurred at disk power-on lifetime: 839 hours (34 days + 23 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 80 00 44 09 e4 Error: UNC 128 sectors at LBA = 0x04094400 = 67716096
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 80 00 44 09 e0 00 00:00:21.463 READ DMA EXT
ef 03 45 00 00 00 a0 00 00:00:21.461 SET FEATURES [Set transfer mode]
ff ff ff ff ff ff ff 0c 00:00:21.450 [VENDOR SPECIFIC]
25 00 80 00 44 09 e0 00 00:00:17.440 READ DMA EXT
ef 03 45 00 00 00 a0 00 00:00:17.439 SET FEATURES [Set transfer mode]
Error 38 occurred at disk power-on lifetime: 839 hours (34 days + 23 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 80 00 44 09 e4 Error: UNC 128 sectors at LBA = 0x04094400 = 67716096
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 80 00 44 09 e0 00 00:00:17.440 READ DMA EXT
ef 03 45 00 00 00 a0 00 00:00:17.439 SET FEATURES [Set transfer mode]
ff ff ff ff ff ff ff 0c 00:00:17.428 [VENDOR SPECIFIC]
25 00 80 00 44 09 e0 00 00:00:13.418 READ DMA EXT
ef 03 45 00 00 00 a0 00 00:00:13.417 SET FEATURES [Set transfer mode]
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 1482 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 625142447 Self_test_in_progress [90% left]
(236847104-236912639)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Try before you buy = See our experts in action!
The most comprehensive online learning library for Microsoft developers
is just $99.99! Visual Studio, SharePoint, SQL - plus HTML5, CSS3, MVC3,
Metro Style Apps, more. Free future releases when you subscribe now!
http://p.sf.net/sfu/learndevnow-dev2
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database