# smartctl  -d sat -a  /dev/sda
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.18-308.1.1.el5xen] (local 
build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD7502ABYS-02A6B0
Serial Number:    WD-WMATV4703352
LU WWN Device Id: 5 0014ee 0ac8c428a
Firmware Version: 03.00C06
User Capacity:    750,156,374,016 bytes [750 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Wed Apr 11 11:22:10 2012 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (15000) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 174) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.
SCT capabilities:              (0x303f) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0027   253   253   021    Pre-fail  Always       
-       1100
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       26
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x002e   100   253   000    Old_age   Always       
-       0
  9 Power_On_Hours          0x0032   075   075   000    Old_age   Always       
-       18560
 10 Spin_Retry_Count        0x0032   100   253   000    Old_age   Always       
-       0
 11 Calibration_Retry_Count 0x0032   100   253   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       25
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       
-       24
193 Load_Cycle_Count        0x0032   200   200   000    Old_age   Always       
-       1
194 Temperature_Celsius     0x0022   110   102   000    Old_age   Always       
-       40
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   200   200   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age   Offline      
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%     18560         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


Attachment: signature.asc
Description: Message signed with OpenPGP using GPGMail

------------------------------------------------------------------------------
For Developers, A Lot Can Happen In A Second.
Boundary is the first to Know...and Tell You.
Monitor Your Applications in Ultra-Fine Resolution. Try it FREE!
http://p.sf.net/sfu/Boundary-d2dvs2
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to