Some weirdness (same on two new identical disks):
#1 Raw_Read_Error_Rate
#7 Seek_Error_Rate
#240 Head_Flying_Hours
Are all very high, but no errors in syslog, and device seems to function
properly.
--
Anders Blomdell Email: anders.blomd...@control.lth.se
Department of Automatic Control
Lund University Phone: +46 46 222 4625
P.O. Box 118 Fax: +46 46 138118
SE-221 00 Lund, Sweden
smartctl 5.42 2011-10-20 r3458 [i686-linux-3.2.7-1.fc16.i686.PAE] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda (SATA 3Gb/s, 4K Sectors)
Device Model: ST2000DM001-9YN164
Serial Number: Z1E0AFLB
LU WWN Device Id: 5 000c50 03fa4c154
Firmware Version: CC4C
User Capacity: 2 000 398 934 016 bytes [2,00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 4
Local Time is: Fri Apr 13 09:56:45 2012 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 73) The previous self-test completed having
a test element that failed and the test
element that failed is not known.
Total time to complete Offline
data collection: ( 575) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 216) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x3085) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 117 100 006 Pre-fail Always
- 131286696
3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always
- 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always
- 4
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always
- 0
7 Seek_Error_Rate 0x000f 028 027 030 Pre-fail Always
FAILING_NOW 10681585037228
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 45
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always
- 4
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always
- 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always
- 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always
- 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always
- 0
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always
- 0
190 Airflow_Temperature_Cel 0x0022 067 058 045 Old_age Always
- 33 (Min/Max 25/39)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always
- 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 3
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always
- 26
194 Temperature_Celsius 0x0022 033 042 000 Old_age Always
- 33 (0 25 0 0 0)
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always
- 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline
- 187217624432679
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline
- 48078611280
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline
- 3800735033
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed: unknown failure 90% 45 0
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
For Developers, A Lot Can Happen In A Second.
Boundary is the first to Know...and Tell You.
Monitor Your Applications in Ultra-Fine Resolution. Try it FREE!
http://p.sf.net/sfu/Boundary-d2dvs2
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net