Some weirdness (same on two new identical disks):
#1   Raw_Read_Error_Rate
#7   Seek_Error_Rate
#240 Head_Flying_Hours

Are all very high, but no errors in syslog, and device seems to function properly.

--
Anders Blomdell                  Email: anders.blomd...@control.lth.se
Department of Automatic Control
Lund University                  Phone:    +46 46 222 4625
P.O. Box 118                     Fax:      +46 46 138118
SE-221 00 Lund, Sweden

smartctl 5.42 2011-10-20 r3458 [i686-linux-3.2.7-1.fc16.i686.PAE] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda (SATA 3Gb/s, 4K Sectors)
Device Model:     ST2000DM001-9YN164
Serial Number:    Z1E0AFLB
LU WWN Device Id: 5 000c50 03fa4c154
Firmware Version: CC4C
User Capacity:    2 000 398 934 016 bytes [2,00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Fri Apr 13 09:56:45 2012 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (  73) The previous self-test completed having
                                        a test element that failed and the test
                                        element that failed is not known.
Total time to complete Offline 
data collection:                (  575) seconds.
Offline data collection
capabilities:                    (0x73) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 216) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x3085) SCT Status supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   117   100   006    Pre-fail  Always       
-       131286696
  3 Spin_Up_Time            0x0003   097   097   000    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       
-       4
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   028   027   030    Pre-fail  Always   
FAILING_NOW 10681585037228
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       45
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       
-       4
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       
-       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       
-       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0022   067   058   045    Old_age   Always       
-       33 (Min/Max 25/39)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       
-       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       3
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       
-       26
194 Temperature_Celsius     0x0022   033   042   000    Old_age   Always       
-       33 (0 25 0 0 0)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      
-       187217624432679
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      
-       48078611280
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      
-       3800735033

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed: unknown failure    90%        45         0

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
For Developers, A Lot Can Happen In A Second.
Boundary is the first to Know...and Tell You.
Monitor Your Applications in Ultra-Fine Resolution. Try it FREE!
http://p.sf.net/sfu/Boundary-d2dvs2
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to