I am deploying new Hitachi 4TB (HDS5C4040ALA630) hard drives on our storage
servers (running GlusterFS). I wanted to submit the following information for
inclusion of this new drive for the smartctl database.
[root@gfs02 ~]# smartctl -a /dev/sdb
smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: Hitachi HDS5C4040ALE630
Serial Number: PL2310LAG0HZLC
Firmware Version: MPAOA250
User Capacity: 4,000,787,030,016 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 4
Local Time is: Sun Jun 24 07:39:42 2012 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command
from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 28) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 255) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always -
0
2 Throughput_Performance 0x0005 135 135 054 Pre-fail Offline -
99
3 Spin_Up_Time 0x0007 142 142 024 Pre-fail Always -
548 (Average 434)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always -
13
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always -
0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always -
0
8 Seek_Time_Performance 0x0005 113 113 020 Pre-fail Offline -
42
9 Power_On_Hours 0x0012 100 100 000 Old_age Always -
705
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always -
0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always -
13
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always -
39
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always -
39
194 Temperature_Celsius 0x0002 176 176 000 Old_age Always -
34 (Lifetime Min/Max 22/47)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always -
0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always -
0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline -
0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always -
0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 705 -
# 2 Short offline Completed without error 00% 316 -
# 3 Short offline Completed without error 00% 292 -
# 4 Short offline Completed without error 00% 268 -
# 5 Short offline Completed without error 00% 244 -
# 6 Short offline Completed without error 00% 220 -
# 7 Short offline Completed without error 00% 196 -
# 8 Short offline Completed without error 00% 175 -
# 9 Short offline Completed without error 00% 148 -
#10 Short offline Completed without error 00% 124 -
#11 Short offline Completed without error 00% 100 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Thanks in advance,
Larry Bates
vitalEsafe, Inc.
------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and
threat landscape has changed and how IT managers can respond. Discussions
will include endpoint security, mobile security and the latest in malware
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database