According to OWC, this is a SandForce Driven SSD. I added the following two lines to the list of SandForce drives in drivedb.h, and everything appears to make sense:
"OWC Mercury Electra (3G|6G) SSD|" // tested with
// OWC Mercury Electra 6G SSD
I've attached test2.txt to show what the data looks like after the above changes. Field 9 appears to be accurate, since I just got this drive yesterday, and it's been running pretty much non-stop since.
Thanks!
"OWC Mercury Electra (3G|6G) SSD|" // tested with
// OWC Mercury Electra 6G SSD
I've attached test2.txt to show what the data looks like after the above changes. Field 9 appears to be accurate, since I just got this drive yesterday, and it's been running pretty much non-stop since.
Thanks!
smartctl 5.42 2011-10-20 r3458 [x86_64-apple-darwin11.4.0] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION === Model Family: SandForce Driven SSDs Device Model: OWC Mercury Electra 6G SSD Serial Number: EX6G12012E22K7386 LU WWN Device Id: 0 000120 000000000 Firmware Version: 502ABBF0 User Capacity: 120,034,123,776 bytes [120 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ACS-2 revision 3 Local Time is: Fri Jun 22 02:18:11 2012 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x0021) SCT Status supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 116 116 050 Pre-fail Always - 0/144287345 5 Retired_Block_Count 0x0033 100 100 003 Pre-fail Always - 0 9 Power_On_Hours_and_Msec 0x0032 000 000 000 Old_age Always - 24h+45m+11.190s 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 12 171 Program_Fail_Count 0x0032 000 000 000 Old_age Always - 0 172 Erase_Fail_Count 0x0032 000 000 000 Old_age Always - 0 174 Unexpect_Power_Loss_Ct 0x0030 000 000 000 Old_age Offline - 13 177 Wear_Range_Delta 0x0000 000 000 000 Old_age Offline - 0 181 Program_Fail_Count 0x0032 000 000 000 Old_age Always - 0 182 Erase_Fail_Count 0x0032 000 000 000 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0000 040 041 000 Old_age Offline - 40 (Min/Max 22/41) 194 Temperature_Celsius 0x0022 040 041 000 Old_age Always - 40 (Min/Max 22/41) 195 ECC_Uncorr_Error_Count 0x001c 120 120 000 Old_age Offline - 0/144287345 196 Reallocated_Event_Count 0x0033 100 100 003 Pre-fail Always - 0 201 Unc_Soft_Read_Err_Rate 0x001c 120 120 000 Old_age Offline - 0/144287345 204 Soft_ECC_Correct_Rate 0x001c 120 120 000 Old_age Offline - 0/144287345 230 Life_Curve_Status 0x0013 100 100 000 Pre-fail Always - 100 231 SSD_Life_Left 0x0013 100 100 010 Pre-fail Always - 0 233 SandForce_Internal 0x0000 000 000 000 Old_age Offline - 43 234 SandForce_Internal 0x0032 000 000 000 Old_age Always - 49 241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always - 49 242 Lifetime_Reads_GiB 0x0032 000 000 000 Old_age Always - 79 SMART Error Log not supported SMART Self-test Log not supported SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
smartctl 5.42 2011-10-20 r3458 [x86_64-apple-darwin11.4.0] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: OWC Mercury Electra 6G SSD Serial Number: EX6G12012E22K7386 LU WWN Device Id: 0 000120 000000000 Firmware Version: 502ABBF0 User Capacity: 120,034,123,776 bytes [120 GB] Sector Size: 512 bytes logical/physical Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ACS-2 revision 3 Local Time is: Fri Jun 22 02:15:33 2012 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x0021) SCT Status supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 116 116 050 Pre-fail Always - 144287339 5 Reallocated_Sector_Ct 0x0033 100 100 003 Pre-fail Always - 0 9 Power_On_Hours 0x0032 000 000 000 Old_age Always - 271880019771416 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 12 171 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 0 172 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 0 174 Unknown_Attribute 0x0030 000 000 000 Old_age Offline - 13 177 Wear_Leveling_Count 0x0000 000 000 000 Old_age Offline - 0 181 Program_Fail_Cnt_Total 0x0032 000 000 000 Old_age Always - 0 182 Erase_Fail_Count_Total 0x0032 000 000 000 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0000 040 041 000 Old_age Offline - 40 (Min/Max 22/41) 194 Temperature_Celsius 0x0022 040 041 000 Old_age Always - 40 (Min/Max 22/41) 195 Hardware_ECC_Recovered 0x001c 120 120 000 Old_age Offline - 144287339 196 Reallocated_Event_Count 0x0033 100 100 003 Pre-fail Always - 0 201 Soft_Read_Error_Rate 0x001c 120 120 000 Old_age Offline - 144287339 204 Soft_ECC_Correction 0x001c 120 120 000 Old_age Offline - 144287339 230 Head_Amplitude 0x0013 100 100 000 Pre-fail Always - 100 231 Temperature_Celsius 0x0013 100 100 010 Pre-fail Always - 0 233 Media_Wearout_Indicator 0x0000 000 000 000 Old_age Offline - 43 234 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 49 241 Total_LBAs_Written 0x0032 000 000 000 Old_age Always - 49 242 Total_LBAs_Read 0x0032 000 000 000 Old_age Always - 79 SMART Error Log not supported SMART Self-test Log not supported SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------ Live Security Virtual Conference Exclusive live event will cover all the ways today's security and threat landscape has changed and how IT managers can respond. Discussions will include endpoint security, mobile security and the latest in malware threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database