According to OWC, this is a SandForce Driven SSD.  I added the following two lines to the list of SandForce drives in drivedb.h, and everything appears to make sense:

    "OWC Mercury Electra (3G|6G) SSD|" // tested with
      // OWC Mercury Electra 6G SSD

I've attached test2.txt to show what the data looks like after the above changes.  Field 9 appears to be accurate, since I just got this drive yesterday, and it's been running pretty much non-stop since.


Thanks!
smartctl 5.42 2011-10-20 r3458 [x86_64-apple-darwin11.4.0] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     SandForce Driven SSDs
Device Model:     OWC Mercury Electra 6G SSD
Serial Number:    EX6G12012E22K7386
LU WWN Device Id: 0 000120 000000000
Firmware Version: 502ABBF0
User Capacity:    120,034,123,776 bytes [120 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ACS-2 revision 3
Local Time is:    Fri Jun 22 02:18:11 2012 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  48) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x0021) SCT Status supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   116   116   050    Pre-fail  Always       
-       0/144287345
  5 Retired_Block_Count     0x0033   100   100   003    Pre-fail  Always       
-       0
  9 Power_On_Hours_and_Msec 0x0032   000   000   000    Old_age   Always       
-       24h+45m+11.190s
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       12
171 Program_Fail_Count      0x0032   000   000   000    Old_age   Always       
-       0
172 Erase_Fail_Count        0x0032   000   000   000    Old_age   Always       
-       0
174 Unexpect_Power_Loss_Ct  0x0030   000   000   000    Old_age   Offline      
-       13
177 Wear_Range_Delta        0x0000   000   000   000    Old_age   Offline      
-       0
181 Program_Fail_Count      0x0032   000   000   000    Old_age   Always       
-       0
182 Erase_Fail_Count        0x0032   000   000   000    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0000   040   041   000    Old_age   Offline      
-       40 (Min/Max 22/41)
194 Temperature_Celsius     0x0022   040   041   000    Old_age   Always       
-       40 (Min/Max 22/41)
195 ECC_Uncorr_Error_Count  0x001c   120   120   000    Old_age   Offline      
-       0/144287345
196 Reallocated_Event_Count 0x0033   100   100   003    Pre-fail  Always       
-       0
201 Unc_Soft_Read_Err_Rate  0x001c   120   120   000    Old_age   Offline      
-       0/144287345
204 Soft_ECC_Correct_Rate   0x001c   120   120   000    Old_age   Offline      
-       0/144287345
230 Life_Curve_Status       0x0013   100   100   000    Pre-fail  Always       
-       100
231 SSD_Life_Left           0x0013   100   100   010    Pre-fail  Always       
-       0
233 SandForce_Internal      0x0000   000   000   000    Old_age   Offline      
-       43
234 SandForce_Internal      0x0032   000   000   000    Old_age   Always       
-       49
241 Lifetime_Writes_GiB     0x0032   000   000   000    Old_age   Always       
-       49
242 Lifetime_Reads_GiB      0x0032   000   000   000    Old_age   Always       
-       79

SMART Error Log not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

smartctl 5.42 2011-10-20 r3458 [x86_64-apple-darwin11.4.0] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     OWC Mercury Electra 6G SSD
Serial Number:    EX6G12012E22K7386
LU WWN Device Id: 0 000120 000000000
Firmware Version: 502ABBF0
User Capacity:    120,034,123,776 bytes [120 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ACS-2 revision 3
Local Time is:    Fri Jun 22 02:15:33 2012 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  48) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x0021) SCT Status supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   116   116   050    Pre-fail  Always       
-       144287339
  5 Reallocated_Sector_Ct   0x0033   100   100   003    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0032   000   000   000    Old_age   Always       
-       271880019771416
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       12
171 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       
-       0
172 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       
-       0
174 Unknown_Attribute       0x0030   000   000   000    Old_age   Offline      
-       13
177 Wear_Leveling_Count     0x0000   000   000   000    Old_age   Offline      
-       0
181 Program_Fail_Cnt_Total  0x0032   000   000   000    Old_age   Always       
-       0
182 Erase_Fail_Count_Total  0x0032   000   000   000    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0000   040   041   000    Old_age   Offline      
-       40 (Min/Max 22/41)
194 Temperature_Celsius     0x0022   040   041   000    Old_age   Always       
-       40 (Min/Max 22/41)
195 Hardware_ECC_Recovered  0x001c   120   120   000    Old_age   Offline      
-       144287339
196 Reallocated_Event_Count 0x0033   100   100   003    Pre-fail  Always       
-       0
201 Soft_Read_Error_Rate    0x001c   120   120   000    Old_age   Offline      
-       144287339
204 Soft_ECC_Correction     0x001c   120   120   000    Old_age   Offline      
-       144287339
230 Head_Amplitude          0x0013   100   100   000    Pre-fail  Always       
-       100
231 Temperature_Celsius     0x0013   100   100   010    Pre-fail  Always       
-       0
233 Media_Wearout_Indicator 0x0000   000   000   000    Old_age   Offline      
-       43
234 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       
-       49
241 Total_LBAs_Written      0x0032   000   000   000    Old_age   Always       
-       49
242 Total_LBAs_Read         0x0032   000   000   000    Old_age   Always       
-       79

SMART Error Log not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to