Greg Dickie
just a guy
514-983-5400
smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.6.3-1.fc17.x86_64] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     OCZ-AGILITY4
Serial Number:    OCZ-56MF37R54VBR7U94
LU WWN Device Id: 5 e83a97 83125a7ab
Firmware Version: 1.5.2
User Capacity:    512,110,190,592 bytes [512 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ACS-2 (revision not indicated)
Local Time is:    Wed Oct 31 13:10:08 2012 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Unavailable
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 249) Self-test routine in progress...
                                        90% of test remaining.
Total time to complete Offline 
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x1d) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging NOT supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   0) minutes.
Extended self-test routine
recommended polling time:        (   0) minutes.

SMART Attributes Data Structure revision number: 18
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     ------   007   000   000    -    7
  3 Spin_Up_Time            ------   100   100   000    -    0
  4 Start_Stop_Count        ------   100   100   000    -    0
  5 Reallocated_Sector_Ct   ------   100   100   000    -    4
  9 Power_On_Hours          ------   100   100   000    -    43
 12 Power_Cycle_Count       ------   100   100   000    -    10
232 Available_Reservd_Space ------   100   100   000    -    15969132721
233 Media_Wearout_Indicator ------   100   000   000    -    100
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 0
SMART           Log Directory Version 1 [multi-sector log support]
GP/S  Log at address 0x00 has    1 sectors [Log Directory]
SMART Log at address 0x06 has    1 sectors [SMART self-test log]
SMART Log at address 0x07 has    1 sectors [Extended self-test log]
SMART Log at address 0x09 has    1 sectors [Selective self-test log]
SMART Log at address 0x10 has    1 sectors [NCQ Command Error log]
SMART Log at address 0xa0 has  255 sectors [Device vendor specific log]

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log (GP Log 0x07) not supported
Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


Device does not support Selective Self Tests/Logging
Warning: device does not support SCT Commands
SATA Phy Event Counters (GP Log 0x11) not supported
------------------------------------------------------------------------------
Everyone hates slow websites. So do we.
Make your web apps faster with AppDynamics
Download AppDynamics Lite for free today:
http://p.sf.net/sfu/appdyn_sfd2d_oct
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to