Hi to all!

I've found that the WD "My Passport USB 3.0" drive and USB bridge are not
in smartctl database.
I've added these lines into the database and now is correctly displayed:

  { "USB: WD My Passport USB 3.0; ", //
    "0x1058:0x07a8",
    "", //
    "",
    "-d sat" //
   },

See also the attachments for device output.
Let me know if more details are needed.

Greetings,
Sam
-- 
google+ <https://plus.google.com/100588827917676584788> |my opensource
project: hdd guardian <http://code.google.com/p/hddguardian>
(smartctl /dev/sdd -d sat -a)

smartctl 6.0 2012-10-10 r3643 [i686-w64-mingw32-xp-sp3] (sf-6.0-1)
Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD5000LMVW-11CKRS0
Serial Number:    WD-WXD1A82E0634
LU WWN Device Id: 5 0014ee 25cc4b204
Firmware Version: 01.01A01
User Capacity:    500.074.308.096 bytes [500 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Tue Nov 27 15:25:59 2012 
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART STATUS RETURN: incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                ( 8580) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  96) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.
SCT capabilities:              (0x70b5) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   253   051    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0027   155   155   021    Pre-fail  Always       
-       1233
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       12
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x002e   100   253   000    Old_age   Always       
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       0
 10 Spin_Retry_Count        0x0032   100   253   000    Old_age   Always       
-       0
 11 Calibration_Retry_Count 0x0032   100   253   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       12
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       
-       7
193 Load_Cycle_Count        0x0032   200   200   000    Old_age   Always       
-       30
194 Temperature_Celsius     0x0022   117   115   000    Old_age   Always       
-       26
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   100   253   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x0008   100   253   000    Old_age   Offline      
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

(smartctl /dev/sdd)

smartctl 6.0 2012-10-10 r3643 [i686-w64-mingw32-xp-sp3] (sf-6.0-1)
Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org

/dev/sdd: Unknown USB bridge [0x1058:0x07a8]
Please specify device type with the -d option.

Use smartctl -h to get a usage summary

------------------------------------------------------------------------------
Keep yourself connected to Go Parallel: 
VERIFY Test and improve your parallel project with help from experts 
and peers. http://goparallel.sourceforge.net
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to