smartctl 6.0 2012-10-10 r3643 [x86_64-apple-darwin12.2.1] (local build)
Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: APPLE SSD SM512E
Serial Number: S118NYACA19963
LU WWN Device Id: 5 002538 043584d30
Firmware Version: CXM0AA1Q
User Capacity: 500,277,790,720 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Dec 3 10:07:27 2012 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1920) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 32) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O-RC- 200 200 000 - 0
5 Reallocated_Sector_Ct PO--CK 100 100 000 - 0
9 Power_On_Hours -O--CK 099 099 000 - 287
12 Power_Cycle_Count -O--CK 099 099 000 - 193
169 Unknown_Attribute PO--C- 253 253 010 - 2826960908800
173 Unknown_Attribute -O--CK 197 197 100 - 4301455365
192 Power-Off_Retract_Count -O--C- 099 099 000 - 2
194 Temperature_Celsius -O---K 060 035 000 - 40 (Min/Max 15/65)
197 Current_Pending_Sector -O---K 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-RC- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not
supported
Read GP Log Directory failed
SMART Log Directory Version 1 [multi-sector log support]
SMART Log at address 0x00 has 1 sectors [Log Directory]
SMART Log at address 0x01 has 1 sectors [Summary SMART error log]
SMART Log at address 0x02 has 2 sectors [Comprehensive SMART error log]
SMART Log at address 0x03 has 2 sectors [Ext. Comprehensive SMART error log]
SMART Log at address 0x06 has 1 sectors [SMART self-test log]
SMART Log at address 0x07 has 2 sectors [Extended self-test log]
SMART Log at address 0x09 has 1 sectors [Selective self-test log]
SMART Log at address 0x10 has 1 sectors [NCQ Command Error log]
SMART Log at address 0x11 has 1 sectors [SATA Phy Event Counters]
SMART Log at address 0x80 has 16 sectors [Host vendor specific log]
SMART Log at address 0x81 has 16 sectors [Host vendor specific log]
SMART Log at address 0x82 has 16 sectors [Host vendor specific log]
SMART Log at address 0x83 has 16 sectors [Host vendor specific log]
SMART Log at address 0x84 has 16 sectors [Host vendor specific log]
SMART Log at address 0x85 has 16 sectors [Host vendor specific log]
SMART Log at address 0x86 has 16 sectors [Host vendor specific log]
SMART Log at address 0x87 has 16 sectors [Host vendor specific log]
SMART Log at address 0x88 has 16 sectors [Host vendor specific log]
SMART Log at address 0x89 has 16 sectors [Host vendor specific log]
SMART Log at address 0x8a has 16 sectors [Host vendor specific log]
SMART Log at address 0x8b has 16 sectors [Host vendor specific log]
SMART Log at address 0x8c has 16 sectors [Host vendor specific log]
SMART Log at address 0x8d has 16 sectors [Host vendor specific log]
SMART Log at address 0x8e has 16 sectors [Host vendor specific log]
SMART Log at address 0x8f has 16 sectors [Host vendor specific log]
SMART Log at address 0x90 has 16 sectors [Host vendor specific log]
SMART Log at address 0x91 has 16 sectors [Host vendor specific log]
SMART Log at address 0x92 has 16 sectors [Host vendor specific log]
SMART Log at address 0x93 has 16 sectors [Host vendor specific log]
SMART Log at address 0x94 has 16 sectors [Host vendor specific log]
SMART Log at address 0x95 has 16 sectors [Host vendor specific log]
SMART Log at address 0x96 has 16 sectors [Host vendor specific log]
SMART Log at address 0x97 has 16 sectors [Host vendor specific log]
SMART Log at address 0x98 has 16 sectors [Host vendor specific log]
SMART Log at address 0x99 has 16 sectors [Host vendor specific log]
SMART Log at address 0x9a has 16 sectors [Host vendor specific log]
SMART Log at address 0x9b has 16 sectors [Host vendor specific log]
SMART Log at address 0x9c has 16 sectors [Host vendor specific log]
SMART Log at address 0x9d has 16 sectors [Host vendor specific log]
SMART Log at address 0x9e has 16 sectors [Host vendor specific log]
SMART Log at address 0x9f has 16 sectors [Host vendor specific log]
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 287 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP Log 0x04) not supported
ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not
supported
Read SATA Phy Event Counters failed
------------------------------------------------------------------------------
LogMeIn Rescue: Anywhere, Anytime Remote support for IT. Free Trial
Remotely access PCs and mobile devices and provide instant support
Improve your efficiency, and focus on delivering more value-add services
Discover what IT Professionals Know. Rescue delivers
http://p.sf.net/sfu/logmein_12329d2d
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database