`smartctl -a` in OCZ-VERTEX-PLUS-R2.txt file
`smartctl -x` in OCZ-VERTEX-PLUS-R2-x.txt file
//wbr ojab
smartctl 5.40 2010-10-16 r3189 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: OCZ-VERTEX PLUS R2
Serial Number: 45HO9W2163X9DU1VU5OE
Firmware Version: 1.2
User Capacity: 247 400 849 408 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue Mar 5 17:38:21 2013 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x1d) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x00) Error logging NOT supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 0) minutes.
Extended self-test routine
recommended polling time: ( 0) minutes.
SMART Attributes Data Structure revision number: 18
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0000 004 000 000 Old_age Offline
- 4
3 Spin_Up_Time 0x0000 100 100 000 Old_age Offline
- 0
4 Start_Stop_Count 0x0000 100 100 000 Old_age Offline
- 0
5 Reallocated_Sector_Ct 0x0000 100 100 000 Old_age Offline
- 0
9 Power_On_Hours 0x0000 100 100 000 Old_age Offline
- 3
12 Power_Cycle_Count 0x0000 100 100 000 Old_age Offline
- 8
232 Available_Reservd_Space 0x0000 100 100 000 Old_age Offline
- 8901
233 Media_Wearout_Indicator 0x0000 100 000 000 Old_age Offline
- 100
Warning: device does not support Error Logging
Warning! SMART ATA Error Log Structure error: invalid SMART checksum.
SMART Error Log Version: 1
No Errors Logged
Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Device does not support Selective Self Tests/Logging
smartctl 5.40 2010-10-16 r3189 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: OCZ-VERTEX PLUS R2
Serial Number: 45HO9W2163X9DU1VU5OE
Firmware Version: 1.2
User Capacity: 247 400 849 408 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue Mar 5 17:38:25 2013 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x1d) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x00) Error logging NOT supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 0) minutes.
Extended self-test routine
recommended polling time: ( 0) minutes.
SMART Attributes Data Structure revision number: 18
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0000 004 000 000 Old_age Offline
- 4
3 Spin_Up_Time 0x0000 100 100 000 Old_age Offline
- 0
4 Start_Stop_Count 0x0000 100 100 000 Old_age Offline
- 0
5 Reallocated_Sector_Ct 0x0000 100 100 000 Old_age Offline
- 0
9 Power_On_Hours 0x0000 100 100 000 Old_age Offline
- 3
12 Power_Cycle_Count 0x0000 100 100 000 Old_age Offline
- 8
232 Available_Reservd_Space 0x0000 100 100 000 Old_age Offline
- 8901
233 Media_Wearout_Indicator 0x0000 100 000 000 Old_age Offline
- 100
General Purpose Logging (GPL) feature set supported
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
GP/S Log at address 0x00 has 1 sectors [Log Directory]
GP/S Log at address 0x01 has 1 sectors [Summary SMART error log]
GP/S Log at address 0x02 has 51 sectors [Comprehensive SMART error log]
GP/S Log at address 0x03 has 77 sectors [Ext. Comprehensive SMART error log]
GP/S Log at address 0x06 has 1 sectors [SMART self-test log]
GP/S Log at address 0x07 has 1 sectors [Extended self-test log]
GP/S Log at address 0x09 has 1 sectors [Selective self-test log]
GP/S Log at address 0x10 has 1 sectors [NCQ Command Error]
GP/S Log at address 0x11 has 1 sectors [SATA Phy Event Counters]
GP Log at address 0xa0 has 4096 sectors [Device vendor specific log]
SMART Extended Comprehensive Error Log Version: 18 (77 sectors)
No Errors Logged
Warning! SMART Extended Self-test Log Structure error: invalid SMART checksum.
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Device does not support Selective Self Tests/Logging
Warning: device does not support SCT Commands
SATA Phy Event Counters (GP Log 0x11)
[Reserved: 0x00 0x00 0x41 0x00]
ID Size Value Description
------------------------------------------------------------------------------
Everyone hates slow websites. So do we.
Make your web apps faster with AppDynamics
Download AppDynamics Lite for free today:
http://p.sf.net/sfu/appdyn_d2d_mar
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database