type = Seagate 600 SSD family ; model nr ST240HN0000
smartctl 6.1 2013-03-16 r3800 [x86_64-apple-darwin11.4.2] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: ST240HM000-1G5152
Serial Number: Z4N004K1
LU WWN Device Id: 5 000c50 02ff0876d
Firmware Version: C675
User Capacity: 240.057.409.536 bytes [240 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Mon Aug 12 22:24:42 2013 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 7) seconds.
Offline data collection
capabilities: (0x19) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 38) minutes.
SMART Attributes Data Structure revision number: 0
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -OSR-- 166 166 006 - 0
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
9 Power_On_Hours -O--CK 100 100 000 - 136
12 Power_Cycle_Count -O--CK 100 100 020 - 44
171 Unknown_Attribute -O--CK 100 100 000 - 0
172 Unknown_Attribute -O--CK 100 100 000 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 000 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 047 000 000 - 47 (Min/Max 28/59)
201 Unknown_SSD_Attribute -O--CK 100 100 000 - 0
204 Soft_ECC_Correction -O--CK 100 100 000 - 0
231 Temperature_Celsius PO--C- 100 100 010 - 0
234 Unknown_Attribute -O--CK 100 100 000 - 751
241 Total_LBAs_Written -O--CK 100 100 000 - 389
242 Total_LBAs_Read -O--CK 100 100 000 - 132
250 Read_Error_Retry_Rate -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not
implemented
Read GP Log Directory failed
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x03 SL R/O 5 Ext. Comprehensive SMART error log
0x04 SL R/O 8 Device Statistics log
0x07 SL R/O 2 Extended self-test log
0x80-0x9f SL R/W 16 Host vendor specific log
0xa8 SL VS 255 Device vendor specific log
0xb7 SL VS 4 Device vendor specific log
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test Log not supported
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP Log 0x04) not supported
ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not
implemented
Read SATA Phy Event Counters failed
Candidate for database ?
I was looking to get the 'endurance' reading (lifetime %)
Best regards
Dirk
------------------------------------------------------------------------------
Get 100% visibility into Java/.NET code with AppDynamics Lite!
It's a free troubleshooting tool designed for production.
Get down to code-level detail for bottlenecks, with <2% overhead.
Download for free and get started troubleshooting in minutes.
http://pubads.g.doubleclick.net/gampad/clk?id=48897031&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database