smartctl -a attached, additionally you can find some info on the attributes here:

<http://www.micron.com/~/media/Documents/Products/Technical Note/Solid State Storage/tnfd21_m500-mu02_smart_attributes.pdf>

e.g. attribute 202 = life left etc.
smartctl 6.2 2013-07-26 r3841 [FreeBSD 9.1-RELEASE amd64] (local 
build)Copyright (C) 2002-13, Bruce Allen, Christian Franke, 
www.smartmontools.org=== START OF INFORMATION SECTION ===Device Model:     
Crucial_CT120M500SSD1Serial Number:    xxxxxxxxxxxxxLU WWN Device Id: 5 00a075 
1093a348bFirmware Version: MU02User Capacity:    120,034,123,776 bytes [120 
GB]Sector Sizes:     512 bytes logical, 4096 bytes physicalRotation Rate:    
Solid State DeviceDevice is:        Not in smartctl database [for details use: 
-P showall]ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 6SATA Version 
is:  SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)Local Time is:    Fri Aug 16 
12:48:49 2013 UTCSMART support is: Available - device has SMART 
capability.SMART support is: Enabled=== START OF READ SMART DATA SECTION 
===SMART overall-health self-assessment test result: PASSEDGeneral SMART 
Values:Offline data collection status:  (0x84) Offline data collection activity 
                                       was suspended by an interrupting command 
from host.                                        Auto Offline Data Collection: 
Enabled.Self-test execution status:      (   0) The previous self-test routine 
completed                                        without error or no self-test 
has ever                                         been run.Total time to 
complete Offline data collection:                (  140) seconds.Offline data 
collectioncapabilities:                    (0x7b) SMART execute Offline 
immediate.                                        Auto Offline data collection 
on/off support.                                        Suspend Offline 
collection upon new                                        command.             
                           Offline surface scan supported.                      
                  Self-test supported.                                        
Conveyance Self-test supported.                                        
Selective Self-test supported.SMART capabilities:            (0x0003) Saves 
SMART data before entering                                        power-saving 
mode.                                        Supports SMART auto save 
timer.Error logging capability:        (0x01) Error logging supported.          
                              General Purpose Logging supported.Short self-test 
routine recommended polling time:        (   2) minutes.Extended self-test 
routinerecommended polling time:        (   9) minutes.Conveyance self-test 
routinerecommended polling time:        (   3) minutes.SCT capabilities:        
      (0x0035) SCT Status supported.                                        SCT 
Feature Control supported.                                        SCT Data 
Table supported.SMART Attributes Data Structure revision number: 16Vendor 
Specific SMART Attributes with Thresholds:ID# ATTRIBUTE_NAME          FLAG     
VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE  1 
Raw_Read_Error_Rate     0x0032   100   100   ---    Old_age   Always       -    
   225  5 Reallocated_Sector_Ct   0x0032   100   100   ---    Old_age   Always  
     -       49152  9 Power_On_Hours          0x0032   100   100   ---    
Old_age   Always       -       4 12 Power_Cycle_Count       0x0032   100   100  
 ---    Old_age   Always       -       3170 Unknown_Attribute       0x0032   
100   100   ---    Old_age   Always       -       19171 Unknown_Attribute       
0x0032   100   100   ---    Old_age   Always       -       0172 
Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -    
   0173 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always    
   -       2174 Unknown_Attribute       0x0032   100   100   ---    Old_age   
Always       -       1181 Program_Fail_Cnt_Total  0x0022   100   100   ---    
Old_age   Always       -       292060004386183 Runtime_Bad_Block       0x0032   
100   100   ---    Old_age   Always       -       0184 End-to-End_Error        
0x0032   100   100   ---    Old_age   Always       -       0187 
Reported_Uncorrect      0x0032   100   100   ---    Old_age   Always       -    
   0188 Command_Timeout         0x0032   100   100   ---    Old_age   Always    
   -       1194 Temperature_Celsius     0x0022   072   059   ---    Old_age   
Always       -       28 (Min/Max 26/41)195 Hardware_ECC_Recovered  0x003a   100 
  100   ---    Old_age   Always       -       1199625888196 
Reallocated_Event_Count 0x0032   100   100   ---    Old_age   Always       -    
   19197 Current_Pending_Sector  0x0032   100   100   ---    Old_age   Always   
    -       0198 Offline_Uncorrectable   0x0030   100   100   ---    Old_age   
Offline      -       0199 UDMA_CRC_Error_Count    0x0032   100   100   ---    
Old_age   Always       -       0202 Unknown_SSD_Attribute   0x0031   100   100  
 ---    Pre-fail  Offline      -       0206 Unknown_SSD_Attribute   0x000e   
100   100   ---    Old_age   Always       -       0SMART Error Log Version: 1No 
Errors LoggedSMART Self-test log structure revision number 1Num  
Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error# 1  Vendor (0xff)       Completed without error       00%    
     3         -SMART Selective self-test log data structure revision number 1 
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS    1        0        0  Not_testing 
   2        0        0  Not_testing    3        0        0  Not_testing    4    
    0        0  Not_testing    5        0        0  Not_testingSelective 
self-test flags (0x0):  After scanning selected spans, do NOT read-scan 
remainder of disk.If Selective self-test is pending on power-up, resume after 0 
minute delay.
------------------------------------------------------------------------------
Get 100% visibility into Java/.NET code with AppDynamics Lite!
It's a free troubleshooting tool designed for production.
Get down to code-level detail for bottlenecks, with <2% overhead. 
Download for free and get started troubleshooting in minutes. 
http://pubads.g.doubleclick.net/gampad/clk?id=48897031&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to