update-smart-drivedb
/usr/share/smartmontools/drivedb.h updated from branches/RELEASE_5_41_DRIVEDB

smartctl -t short /dev/sda
smartctl 5.41 2011-06-09 r3365 [i686-linux-3.2.0-67-generic] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Warning: device does not support Self-Test functions.

Sending command: "Execute SMART Short self-test routine immediately in off-line 
mode".
Command "Execute SMART Short self-test routine immediately in off-line mode" 
failed: scsi error aborted command


smartctl -x /dev/sda

smartctl 5.41 2011-06-09 r3365 [i686-linux-3.2.0-67-generic] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     mSATA mini 3ME
Serial Number:    20140411AAA100000002
Firmware Version: S130604
User Capacity:    32.017.047.552 bytes [32,0 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   9
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Thu Aug 14 13:50:49 2014 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Total time to complete Offline
data collection:                (   32) seconds.
Offline data collection
capabilities:                    (0x00)         Offline data collection not 
supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging NOT supported.
                                        General Purpose Logging supported.
SCT capabilities:              (0x0039) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     ------   000   000   000    -    0
  2 Throughput_Performance  ------   000   000   000    -    0
  3 Spin_Up_Time            ------   000   000   000    -    0
  5 Reallocated_Sector_Ct   ------   000   000   000    -    0
  7 Seek_Error_Rate         ------   000   000   000    -    0
  8 Seek_Time_Performance   ------   000   000   000    -    0
  9 Power_On_Hours          ------   000   000   000    -    891
 10 Spin_Retry_Count        ------   000   000   000    -    0
 12 Power_Cycle_Count       ------   000   000   000    -    15
  1 Raw_Read_Error_Rate     ------   000   000   000    -    0
168 Unknown_Attribute       ------   000   000   000    -    0
169 Unknown_Attribute       ------   000   000   000    -    0
  1 Raw_Read_Error_Rate     ------   000   000   000    -    0
175 Program_Fail_Count_Chip ------   100   000   000    -    0
192 Power-Off_Retract_Count ------   000   000   000    -    0
  1 Raw_Read_Error_Rate     ------   000   000   000    -    2199023255552
197 Current_Pending_Sector  ------   000   000   000    -    0
240 Head_Flying_Hours       ------   000   000   000    -    0
170 Unknown_Attribute       PO----   100   100   ---    -    851968
173 Unknown_Attribute       -O--C-   100   100   ---    -    7929892
229 Unknown_Attribute       -O----   100   100   ---    -    4415368369304
236 Unknown_Attribute       -O----   100   100   ---    -    0
235 Unknown_Attribute       -O----   100   000   ---    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

Read SMART Log Directory failed.

ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: scsi error aborted 
command
Read GP Log Directory failed.

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test Log not supported
Device does not support Selective Self Tests/Logging
Error Read SCT Status failed: scsi error aborted command
Error Read SCT Status failed: scsi error aborted command
Warning: device does not support SCT (Get) Error Recovery Control command

SATA Phy Event Counters (GP Log 0x11) not supported

------------------------------------------------------------------------------