smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.32-32-pve] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     INTEL SSDSA2VP020G2
Serial Number:    CVLC1280009M020AGN
LU WWN Device Id: 5 001517 9595cf19b
Firmware Version: 2CV102M5
User Capacity:    20,014,718,976 bytes [20.0 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 1
Local Time is:    Fri Oct 17 12:03:58 2014 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (    1) seconds.
Offline data collection
capabilities:                    (0x71) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (   1) minutes.
Conveyance self-test routine
recommended polling time:        (   1) minutes.

SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  3 Spin_Up_Time            0x0020   100   100   000    Old_age   Offline      
-       0
  4 Start_Stop_Count        0x0030   100   100   000    Old_age   Offline      
-       0
  5 Reallocated_Sector_Ct   0x0032   100   100   000    Old_age   Always       
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       22050
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       36
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       7
225 Load_Cycle_Count        0x0030   100   100   000    Old_age   Offline      
-       106164
226 Load-in_Time            0x0032   100   100   000    Old_age   Always       
-       5061585
227 Torq-amp_Count          0x0032   100   100   000    Old_age   Always       
-       1
228 Power-off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       1019548649
232 Available_Reservd_Space 0x0033   100   100   010    Pre-fail  Always       
-       0
233 Media_Wearout_Indicator 0x0032   099   099   000    Old_age   Always       
-       0
184 End-to-End_Error        0x0033   100   100   090    Pre-fail  Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Offline             Completed without error       00%     22050         -

Note: selective self-test log revision number (0) not 1 implies that no 
selective self-test has ever been run
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been 
run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Comprehensive Server Monitoring with Site24x7.
Monitor 10 servers for $9/Month.
Get alerted through email, SMS, voice calls or mobile push notifications.
Take corrective actions from your mobile device.
http://p.sf.net/sfu/Zoho
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to