smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.32-26-pve] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: INTEL SSDSC2BA100G3
Serial Number: BTTV434402SJ100FGN
LU WWN Device Id: 5 5cd2e4 04b6c8eeb
Firmware Version: 5DV10270
User Capacity: 100.030.242.816 bytes [100 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ACS-2 revision 3
Local Time is: Mon Oct 20 10:58:17 2014 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 2) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 2) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 238
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 4
170 Unknown_Attribute 0x0033 100 100 010 Pre-fail Always
- 0
171 Unknown_Attribute 0x0032 100 100 000 Old_age Always
- 0
172 Unknown_Attribute 0x0032 100 100 000 Old_age Always
- 0
174 Unknown_Attribute 0x0032 100 100 000 Old_age Always
- 0
175 Program_Fail_Count_Chip 0x0033 100 100 010 Pre-fail Always
- 8865251947
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always
- 0
184 End-to-End_Error 0x0033 100 100 090 Pre-fail Always
- 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always
- 0
190 Airflow_Temperature_Cel 0x0022 079 078 000 Old_age Always
- 21 (Min/Max 15/27)
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 0
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always
- 28
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always
- 0
199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always
- 0
225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always
- 43298
226 Load-in_Time 0x0032 100 100 000 Old_age Always
- 30
227 Torq-amp_Count 0x0032 100 100 000 Old_age Always
- 0
228 Power-off_Retract_Count 0x0032 100 100 000 Old_age Always
- 14280
232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always
- 0
233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always
- 0
234 Unknown_Attribute 0x0032 100 100 000 Old_age Always
- 0
241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always
- 43298
242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always
- 179
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 238 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Comprehensive Server Monitoring with Site24x7.
Monitor 10 servers for $9/Month.
Get alerted through email, SMS, voice calls or mobile push notifications.
Take corrective actions from your mobile device.
http://p.sf.net/sfu/Zoho
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database