Hello Everyone,
I have been reading about this issue for a couple of hours
now, and yet to see a good resolution for it. I added an external nic on
my SmartOS host in this manner (in /usbkey/config):
# External Nic
external_nic=0:15:17:a7:51:b4
external_ip=192.168.1.2
external_netmask=255.255.255.0
external_gateway=192.168.1.1
The Global Zone image is this:
[root@cfSOS1 /opt/vmdefs]# uname -a
SunOS cfSOS1 5.11 joyent_20170831T155808Z i86pc i386 i86pc
And now when I try and create a Firewall/NAT zone I get the following:
[root@cfSOS1 /opt/vmdefs]# vmadm create -f nat.json
timed out waiting for /var/svc/provisioning to move for
afd88369-6d57-4d52-99c7-8b20bf06e2c6
The image I am using is this:
e1faace4-e19b-11e5-928b-83849e2fd94a minimal-64-lts
15.4.1 smartos zone-dataset 2016-03-03
The json file is this:
{
"brand": "joyent",
"image_uuid": "e1faace4-e19b-11e5-928b-83849e2fd94a",
"autoboot": true,
"alias": "nat",
"hostname": "nat.cfs.loc",
"dns_domain": "cfs.loc",
"resolvers": [
"8.8.8.8",
"8.8.4.4"
],
"max_physical_memory": 512,
"nics": [
{
"nic_tag": "admin",
"ip": "192.168.10.254",
"gateway": "192.168.1.254",
"netmask": "255.255.255.0",
"allow_ip_spoofing": true,
"primary": true
},
{
"nic_tag": "external",
"ip": "dhcp",
"allow_ip_spoofing": true
}
]
}
I tried this:
[root@cfSOS1 /opt/vmdefs]# zoneadm -z
afd88369-6d57-4d52-99c7-8b20bf06e2c6 boot
and the result was this:
UUID TYPE RAM STATE ALIAS
afd88369-6d57-4d52-99c7-8b20bf06e2c6 OS 512 failed nat
2ecf6908-579f-4dc5-ff21-f0b61bf0b547 OS 3072 running cfFifo
I have and can delete the zone and recreate it however it fails everytime.
I am not sure what to do at this point or even how to troubleshoot what
I am seeing, Any help would be greatly appreciated.
This reason for this particular image is I can't get Triton Datacenter
to boot on any of my Dell Servers with Intel Xeon 5420 processors, so I
found a workaround in the Project FIFO and they said this was the latest
image they tested with.
For completeness sake I was able to ping the external gateway and
google, results follow:
[root@cfSOS1 /opt/vmdefs]# ping 192.168.1.1
192.168.1.1 is alive
[root@cfSOS1 /opt/vmdefs]# ping google.com
google.com is alive
Now I also have the admin nic working as well (I am able to ping the
second SmartOS host I have):
[root@cfSOS1 /opt/vmdefs]# ping 192.168.10.4
192.168.10.4 is alive
So the Nics are working fine.
Thanks in Advance,
--
*Michael A Cooper*
Linux Certified Professional
http://www.coopfire.com
-------------------------------------------
smartos-discuss
Archives: https://www.listbox.com/member/archive/184463/=now
RSS Feed: https://www.listbox.com/member/archive/rss/184463/25769125-55cfbc00
Modify Your Subscription:
https://www.listbox.com/member/?member_id=25769125&id_secret=25769125-7688e9fb
Powered by Listbox: http://www.listbox.com