Quoth Peter Memishian on Thu, Jan 17, 2008 at 06:19:30PM +0800: > It seems that "svccfg refresh" is not a complete fix after all. The > problem is that for BFU or Live Upgrade, the system performing the upgrade > may (and unless it's running build 82) will not yet have this command -- > so the refresh won't be done and thus first boot will fail to properly > configure networking. For systems with aggregations, the configuration > for those aggregations will require manual intervention to restore. > > I'd think running manifest-import earlier in boot would be a complete fix > to this issue, but it's not clear to me what the schedule of that work is.
It won't be done within the next month. > Until that fix is available though, the alternatives seem limited -- the > only one that occurs to me is to have net-physical manually start dlmgmtd > (through svcadm if possible, though previous attempts to do this failed). Why did they fail? If nothing else, we can instruct people to refresh network/physical manually and reboot, right? David