On Wed, Sep 17, 2008 at 07:26:28AM +0200, Tobias Oetiker wrote: > at the moment smokeping runs on a single step size ... if you need > different checking intervals you have to run two copies.
No, probe-specific step sizes should work. I don't think that's the problem here. Justin, when you have multiple probe instances, the top section does not define a probe in itself. See the smokeping_examples document, example 3: config.fping-instances. Hope this helps, -- Niko _______________________________________________ smokeping-users mailing list [email protected] https://lists.oetiker.ch/cgi-bin/listinfo/smokeping-users