I don't think the boot count needs to be monotonically increasing. I believe the boot count only needs to be unique within the time window (maybe 2 minutes). Eventually any boot count will roll over and the application needs to handle that case. Are you sure it is related to the boot count?
Error 1414 is: "SNMPv3: USM: Address error" -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Aidan Diffey Sent: Monday, January 18, 2010 10:31 AM To: [email protected] Subject: [SNMP4J] SNMP Manager re-installation no longer authenticating Hello. I have an SNMP device which is connected to a manager (A J2EE application). They are both talking to each other using SNMP V3. I have re-installed the manager which involved reloading a database. This has reset the engine boot count on the manager from 21 back to 1. Since then, I am receiving a -1414 error from SNMP4J. Is there something in SNMP4J that requires the engine boots to be incremented in order for authentication to take place? How would I get the devices talking again after rebuilding the manager database? Kind Regards _______________________________________________ SNMP4J mailing list [email protected] http://lists.agentpp.org/mailman/listinfo/snmp4j _______________________________________________ SNMP4J mailing list [email protected] http://lists.agentpp.org/mailman/listinfo/snmp4j