Hi, On 18.01.2010 16:30, Aidan Diffey wrote: > Hello. > > I have an SNMP device which is connected to a manager (A J2EE application). > They are both talking to each other using SNMP V3. I have re-installed the > manager which involved reloading a database. > This has reset the engine boot count on the manager from 21 back to 1. Since > then, I am receiving a -1414 error from SNMP4J.
This is absolutely normal. Either do not reset the boot counter or delete the cached boot counter information. > > Is there something in SNMP4J that requires the engine boots to be > incremented in order for authentication to take place? This is a SNMPv3 requirement, nothing SNMP4J requires. > > How would I get the devices talking again after rebuilding the manager > database? Let SNMP4J rediscover the engine ID of the device. Use Snmp.discoverEngineID(..) Best regards, Frank -- AGENT++ http://www.agentpp.com http://www.snmp4j.com http://www.mibexplorer.com http://www.mibdesigner.com _______________________________________________ SNMP4J mailing list [email protected] http://lists.agentpp.org/mailman/listinfo/snmp4j