Eric Wong <normalper...@yhbt.net>:

>> Not necessarily, for codecs using compression, it may be impossible to
>> say how much space one sample takes, as this may change, or the term
>> may be inapplicable (e.g., for frequency-domain expression).
> For compression, then shouldn't -b be the maximum bits-per-sample
> decoding the file will give? (which should match precision, I think?)

The simple case is integer PCM, where bits per sample equals  
precision. But there is also floating-point PCM (32 bps, 25  
precision), ADPCM (4 bps, 13-or-so precision), FLAC (varying bps,  
8/16/24 precision), and Vorbis. That's why I think the inconsistency  
actually is a non-zero bps value for FLAC.

> Perhaps there should there be a '-p' flag for show precision in soxi?
> That would match the "Precision" field when soxi is called without
> switches...

Yes, that's good. Done. :-)

Ulrich


------------------------------------------------------------------------------