On Sat, 28 Jul 2007, David Miller wrote:
From: Mark Fortescue <[EMAIL PROTECTED]> Date: Sun, 29 Jul 2007 03:17:39 +0100 (BST)The serial console code selection code needs to select the ports the otherway around. The attached patch fixes the problem. --- linux-test/arch/sparc/kernel/prom.c~ 2007-07-28 21:02:31.000000000 +0100 +++ linux-test/arch/sparc/kernel/prom.c 2007-07-29 02:38:54.000000000 +0100 @@ -460,7 +460,7 @@ strcpy(of_console_path, dp->full_name); if (!strcmp(type, "serial")) { strcat(of_console_path, - (skip ? ":b" : ":a")); + (skip ? ":a" : ":b")); } break;I don't understand this fix :-) We set skip to "1" only if *romvec->pv_stdout is PROMDEV_TTYB, therefore should definitely use ":b" when it is non-zero, which is what the code is doing.
Yes but then you do a !skip-- so 0 -> -1 and 1 -> 0
Perhaps the logic drivers/serial/sunzilog.c or drivers/serial/suncore.c is what is reversed instead.
- To unsubscribe from this list: send the line "unsubscribe sparclinux" in the body of a message to [EMAIL PROTECTED] More majordomo info at http://vger.kernel.org/majordomo-info.html