Guessing you are on windows.. right? 1. open a dos prompt. 2. change to your $SPECROOT/Install-Tools/SRM-Tools/ directory 3. issue command: net stop spectrumtomcat (or stop it via services) 4. issue command: bash 5. issue command: ./setup_boxi.sh 6. issue command: net start spectrumtomcat (or start it via services) 7. issue exit 8. close dos window
your are done Regards, Christian Schneider Enterprise Service Specialist 4-tune GmbH Sägereistrasse 29 CH-8152 Glattbrugg Tel +41 71 930 07 00 Fax +41 71 930 07 01 Mob +41 79 418 45 42 Mail [email protected] Am 18.12.2008 um 21:21 schrieb Vicente Buritica: > Guys, > > I'm seeing an issue after installing H14 and ReportMgr is saying > "The BOXI reporting engine has not been set up...". Any help on how > to resolve this without losing my data? > > Thanks, > Vicente > --To unsubscribe from spectrum, send email to [email protected] with > the body: unsubscribe spectrum [email protected] --- To unsubscribe from spectrum, send email to [email protected] with the body: unsubscribe spectrum [email protected]