Hi Prashant

If you are monitoring a primary ISDN link then by default its their.
You just need to configure the aging parameter as per my
understanding. Just search for that and test.

If your ISDN link is secondary, in that case you might be needing
interval, ISDN number for which it is fired. In this scenario, you
need to capture the specific trap and write alert on it consisting of
event info you require.


Warm Regards:
Gaurav Partap

On Fri, Mar 27, 2009 at 6:14 PM, Prashant <[email protected]> wrote:
> Hi List,
> I do have query:
> when our ISDN link gets up/down frequently e.g flaps 10 times in 5 min
> polling interval.I need to generate alarm only when the threshold for no of
> flaps is violated.
> As in the above case i want alarm for the 11th flap in 5 min polling
> interval of the ISDN link to be generated, because for each flap , no of
> alarms will be quite high. Hence the frequency of alarm can help us generate
> the intelligent alarm.
>
>
> Thanks is advance.
>
>
>
>
> Prashant Thakur
>
> ---
> To unsubscribe from spectrum, send email to [email protected] with the body:
> unsubscribe spectrum [email protected]
>



-- 
Behind an able man, there are always other able men……………….(GAURAV PARTAP)

---