Thanks Rob! It compiled and loaded without a problem. Calvin Lane
On Tue, Aug 3, 2010 at 4:51 PM, Esdale, Robert W <[email protected]>wrote: > Hi Calvin, > > > > The attached one works. I made 2 edits: > > > > 1) Added a comma between “TRAP-TYPE” and “enterprises” in the IMPORT > Statement > > 2) Changed “nimsoft.sysadm” to “sysadm” on line 168, after “ENTERPRISE” > in the NimBUSAlarm Trap > > > > Let me know if you have any problems with this one. Good luck. > > > > > > *Rob Esdale* > CA Technologies > > Sr. Services Consultant > Mobile: +1-603-553-2593 > > [email protected] > > *[image: cid:[email protected]]* <http://www.ca.com/> > > > > > > > > > > *From:* Calvin Lane [mailto:[email protected]] > *Sent:* Tuesday, August 03, 2010 4:29 PM > *To:* spectrum > *Cc:* spectrum > *Subject:* Re: [spectrum] Errors compiling MIB > > > > Thanks Mark. Here it comes with the attachement. > > On Tue, Aug 3, 2010 at 3:54 PM, Mark Serencha < > [email protected]> wrote: > > Hard to tell from raw text. > > Can you re-post as an attachment? > > > > I can’t promise that I will have time to check, but others might ;-) > > > > > > *From:* Calvin Lane [mailto:[email protected]] > *Sent:* Tuesday, August 03, 2010 3:44 PM > *To:* spectrum > *Subject:* [spectrum] Errors compiling MIB > > > > Hello List, > > > > When trying to complile Nimsoft.mib, I get the following error messages: > > > > Could not parse the file NIMSOFT-MIB. The error occured at the line no: 12 > ,column: 9. > > > > Could not parse the file NIMSOFT-MIB. The error occured at the line no: 168 > ,column: 37. > The identifier should not start or end with number or special character. > > > > Can someone tell me what is wrong with this MIB file. Thanks in advance. > > > > Calvin Lane > > > > _____________________________________________________ > > > > NIMSOFT-MIB DEFINITIONS ::= BEGIN > > -- NIMSOFT-MIB { iso org(3) dod(6) internet(1) 4 1 4055} > > -- NIMSOFT enterprise specific MIB > > -- HISTORY: > > -- 2010/05/11 added alarmSuppressionKey, alarmProbeId, alarmUserTag1, > alarmUserTag2, alarmSource, alarmOrigin, alarmTime, alarmTimezoneOffset, > alarmNimId, alarmRobot, alarmDomain > > -- added IMPORTS of enterprises and changed the refering MIB to SNMPv2-SMI > (from RFC-1215) > > IMPORTS > > TRAP-TYPE > > enterprises > > FROM SNMPv2-SMI; > > nimsoft OBJECT IDENTIFIER ::= { enterprises 4055 } > > sysadm OBJECT IDENTIFIER ::= { nimsoft 1 } > > alarm OBJECT IDENTIFIER ::= { sysadm 1 } > > -- the Alarm group > > alarmSeverity OBJECT-TYPE > > SYNTAX INTEGER { > > unknown(0), > > information(1), > > warning(2), > > minor(3), > > major(4), > > critical(5) > > } > > ACCESS read-only > > STATUS mandatory > > DESCRIPTION > > "The alarmSeverity object type is used to > > describe the level of severity of the > > alarm." > > ::= { alarm 1 } > > alarmSubsys OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS mandatory > > DESCRIPTION > > "The alarmSubsys object type is used to > > describe the subsystem (i.e. the service) > > within the NimBUS Alarm Server where the alarm > > occured." > > ::= { alarm 2 } > > alarmDescr OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS mandatory > > DESCRIPTION > > "The alarmDescr object type is used to give a > > textual description of a NimBUS alarm." > > ::= { alarm 3 } > > alarmSuppressionKey OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmSuppression object type is used to give a > > uniquie identifier of a NimBUS alarm." > > ::= { alarm 4 } > > alarmProbeId OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmProbeId object type is used to identify > > the probe that issued the of a NimBUS alarm." > > ::= { alarm 5 } > > alarmUserTag1 OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmUserTag1 object type is used for > > the custom User Tag 1 field of a NimBUS alarm." > > ::= { alarm 6 } > > alarmUserTag2 OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmUserTag2 object type is used for > > the custom User Tag 2 field of a NimBUS alarm." > > ::= { alarm 7 } > > alarmSource OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmSource object type is used to identify > > the source of a NimBUS alarm." > > ::= { alarm 8 } > > alarmOrigin OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmOrigin object type is used to identify > > the origin of a NimBUS alarm." > > ::= { alarm 9 } > > alarmTime OBJECT-TYPE > > SYNTAX INTEGER > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmTime object type is used to identify > > the time of a NimBUS alarm." > > ::= { alarm 10 } > > alarmTimezoneOffset OBJECT-TYPE > > SYNTAX INTEGER > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmTimezoneOffset object type is used to identify > > the timezone offset of a NimBUS alarm." > > ::= { alarm 11 } > > alarmNimId OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmNimId object type is used to identify > > a NimBUS alarm." > > ::= { alarm 12 } > > alarmRobot OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmRobot object type is used to identify > > the Nimsoft Robot that issued a NimBUS alarm." > > ::= { alarm 13 } > > alarmDomain OBJECT-TYPE > > SYNTAX OCTET STRING > > ACCESS read-only > > STATUS optional > > DESCRIPTION > > "The alarmDomain object type is used to identify > > the Nimsoft Domain that issued a NimBUS alarm." > > ::= { alarm 14 } > > -- Enterprise-specific traps to be sent from NIMSOFT Servers > > -- The trap definitions are compliant with RFC 1155, > > -- RFC 1212, and RFC 1215 > > -- > > -- Depends on the snmpgtw probe. It can be configured to map severity > levels to > > -- specific trap numbers. E.g. severity level = 1 maps to specific trap # 1 > > NimBUSAlarm TRAP-TYPE > > ENTERPRISE nimsoft.sysadm > > VARIABLES { sysDescr, alarmLevel, alarmSubsys, alarmDescr, > alarmSuppressionKey, alarmProbeId, alarmUserTag1, alarmUserTag2, > alarmSource, alarmOrigin, alarmTime, alarmTimezoneOffset, alarmNimId, > alarmRobot, alarmDomain} > > DESCRIPTION > > "A NimBUS Alarm trap signifies that the > > sending SNMP application entity recognizes > > a NimBUS Alarm condition in its > > NimBUS Server" > > ::= 2 > > END > > ________________________________ > > > - --To unsubscribe from spectrum, send email to [email protected] with > the body: unsubscribe spectrum [email protected] > > > > - --To unsubscribe from spectrum, send email to [email protected] with > the body: unsubscribe spectrum [email protected] > > --- To unsubscribe from spectrum, send email to [email protected] with the body: unsubscribe spectrum [email protected]
<<image001.png>>