On Tue, 17 Jul 2007 09:11:15 -0700
David Brownell <[EMAIL PROTECTED]> wrote:

> 
> Curious.  I think it was Jan Nikitenko who reported mode 0 not
> working for SD, while mode 3 did work.  All my recent testing
> used mode 3, but I started with mode 0...
> 
> Ideally, someone with access to full MMC and SD specs can see
> what they say about the SPI clocking.  The simplified SD specs
> omit the timing diagrams.
>  

I can probably help out there.

According to the specs, both mode 0 and mode 3 are valid. The idle
polarity simply isn't specified, only that data shall be sampled on
rising edge. Hence mode 0 or 3.

Rgds
-- 
     -- Pierre Ossman