On 21 Feb 2009 at 17:01, Daniel Parrott wrote:

Has anyone tried to re-wire the circuit so that the fan
can continue to operate even after the car is shut down?

Jim Muller's observations are all valid and sensible. I've had a number of modern Euroboxes over the last 20 odd years whose electric fans ran briefly after switch-off. Querying why they did this and purely out of curiousity I noted that:

1 A still running electric fan was only on hot days or after prolonged idling 
in traffic, and
2. The 'stat was opening and closing far more frequently than I'd appreciated. I tested that with a lab jar, thermometer and the 'stat on the household cooker!

I noticed too that sometimes the fan would cut in again after a few minutes and run for up to half a minute. This was operated by a small thermoswitch in the cooling system as an OE fitment and got activated with a continuing supply of overheated water through syphoning and entering the radiator via the 'stat jiggle pin which in turn raised the temperature of the water in the rad.

All the cars in question had mainly alloy engines and this enabled them to cool down far faster than cast-iron units, so what is the main reason behind the query Daniel?