Walter Zamora wrote:
I recently upgraded to your enhanced version of SQL-Ledger using your git instructions. Although everything seemed fine, I do not get any output from the "stock assembly" report in "More Reports". What have I done wrong?
Hi Walter,

This report shows information from new table 'build'. This table is empty on upgrade and gets populated only when you use 'Stock Assembly' process *after* upgrading to the enhanced version.

To convert your old data to use this table, you will need to run the queries mentioned here: > http://ledger123.com/docs/doku.php?id=warehouses#enabling_multiple_warehouses_for_old_dataset

Running these queries is highly recommended even if you have a single warehouse. (plz have a good backup before doing all this)

Let me know if you need further information.

Regards
Armaghan
--
http://www.ledger123.com/

_______________________________________________
SQL-Ledger mailing list
[email protected]
http://lists.ledger123.com/mailman/listinfo/sql-ledger

Reply via email to