Dave,

The flue area / grate area ratio on my coal-fired boiler for an RH Billy
turned out to be 1:9.5, and it steams just fine. The high ratio was not by
plan but because of my own miscalculation when figuring out the required
grate area. My goal had been Harris' 1:6 and 1:7 guidelines.

Earlier I had researched, as you have done, ratios from other gauge 1 boiler
designs. I found ratios from 1:4 up to 1:12 or so. There are other factors
that come into play, obviously, that determine whether a boiler/firebox will
burn coal and make steam. Harris' numbers are a good starting point,
though. Remember, too, that Harris was interested in larger locos (ride on
and ride behind) which might have more exacting boiler performance
requirements than gauge 1 locos do.

What do you figure is the maximum grate size that you can get into the loco
you're planning to convert?  Is it the same Bumble Bee?
Steve Shyvers